Rinnai RH-9020A Скачать руководство пользователя страница 6

 

  Operating Instruction 

 

 

 

     
 
   

 

Light Control    Delay Button    Turbo Speed    Middle Speed      Low Speed    Power Control       

              Button                                      Button        Control Button    Control Button      Button     

           

 

Power control button (Red light) 

1. Push this button to turn on the power and power indicator light will be on.   
2. Push again to turn off power

power indicator light and all functions. 

    Note:If power has been turned on over 9 minutes without any setting 

system will be 

            shut down automatically for energy-saving. 
3. For easy to clean the unit, press the power button 5 sec will automatic locked the   
    button function, at this moment the function board no function when the power light   
    twinkle. Press the power button 5 sec will unlock the it. And will power off. 
 

Speed setting control button(Blue light) 

1. Push turbo button to start extremely turbo speed revolution and turbo indicator light 
    will be on . Push again to turn off speed function only. 

 

2. Push middle speed button to turn on middle speed ventilation and middle speed   
    Indicator will be on. Push again to turn off speed function only.   
3. Push low speed button to turn on low speed ventilation and low speed indicator light   
    will be on. Push again to turn off speed function only.   
 

Delay button(Green light) 

Push delay button to turn on low speed ventilation and delay indicator light will be on , 
system will shut down automatically after 90 seconds. Push again to turn off delay 
function only.   

Only for low speed 

 

Light control button (Orange light) 

1. Push this button to turn on the illumination and light indicator light will be on .   
2. Push again to turn off the LED illumination only.   
    Note:If only push Speed/Delay/Light button, power also will be on.   

 

CAUTION: 

Each button function must press 0.5sec to activate, this is avoid the program hand up 
when pressing the button too fast. 

 

 

                                                                           

  5 

 

 

Содержание RH-9020A

Страница 1: ...tion Maintenance Cleaning Trouble Shooting Warranty Wiring Diagram COOKER HOOD INSTRUCTION MANUAL NAME PAGE Products and accessory 1 Dimensions 2 Caution 4 Operating Instruction 5 Maintenance Cleaning 6 Trouble Shooting 7 Wiring Diagram 8 Specification 9 Model RH 9020A Instruction 3 ...

Страница 2: ...pipe 1 PCS For Fixing Assy screw 2 PCS For Aluminium Tube screw 3 PCS 1 Electric Box Cover Power cable Tube top cover Fan Blade Left Ventilator seal Body Capacitor Control Board Fan Blade Right Motor Ventilator Body Oil Plate Main Tube Unit LED Light Control Panel Electric Box Oil Cup base LED Back Light Glass Mesh Filter Control Panel box Control Panel cover Oil Cup ...

Страница 3: ...mensions 2 MODEL A B C RH 9020A 210mm 896mm 507mm Hook Location A 210 C 75 500 30 343 153 6 408 343 B 896 507 290 285 428 300mm 298mm 896mm 75mm 507mm min 470 max 910 mm Excluding with height of main unit ...

Страница 4: ...al level 300mm 298mm 896mm 75mm 507mm min 470 max 910 mm Excluding with height of main unit 75 90cm Install alum inium tube bracket according to the kitchen cabinet design Find the suitable location and install it on the wall fig 1 A djust alum inium tube height according to the kitchen cabinet design Insert the alum in ium tube into the indentation fig 2 Screw the upper alum inium tube and the br...

Страница 5: ... uninstall 1 Please keep a minimum 75 90 cm distance between cooker hood and cooker Different types of cooker might require a bigger space fig2 fig2 2 Do not flame under the cooker hood fig3 fig3 3 Adjust the aluminium tube to make sure all the exhaust air has blown out successful 4 There shall be adequate ventilation of the room when the cooker hood is used at the same time as appliances burning ...

Страница 6: ...urbo speed revolution and turbo indicator light will be on Push again to turn off speed function only 2 Push middle speed button to turn on middle speed ventilation and middle speed Indicator will be on Push again to turn off speed function only 3 Push low speed button to turn on low speed ventilation and low speed indicator light will be on Push again to turn off speed function only Delay button ...

Страница 7: ...ray water directly on the cooker hood to avoid electric shock or damage to it 6 Use mild detergent to clean the impeller Pull out the oil cup and wash it 7 Always wash or change the filter and clean up the cooker hood regularly 8 Minimum clean up the cooker hood once a week 9 Kindly follow this cleaning instruction to avoid dangerous 10 If the supply cord is damaged it must be replaced by the manu...

Страница 8: ...mpeller deformed 3 Weak Suction Far distance between cooker hood and glass hob Check if aluminum pipe is too long or curve Change to 7 inch diameter if necessary Check if there is excess ventilation Check the aluminum pipe make sure exhaust air and flame blow out smoothly Window should be closed while operating cooker hood 4 Oil Plate Broke Please get the original parts from any authorize dealers ...

Страница 9: ...g Diagram RH 9020A 8 GRAY BLUE WHITE ELECTRIC BOARD Control Board LAMP LAMP BLACK LED Back Light POWER CONDENSER MOTOR YELLOW WHITE BLUE GRAY WHITE YELLOW BROWN WHITE BROWN WHITE BLACK BLACK BLACK BLUE FUSE ...

Страница 10: ...85mm Height From button of main unit OUTLET DIA 153mm FAN SIZE 14CMx2 MOTOR S 1 INSULATION E VOLTTAGE FREQUENCY 240V 50Hz AMP 1 5A LIGHT 2W SPEED Ⅰ Ⅱ Ⅲ MOTOR SPEED 1200rpm 1800rpm 2400rpm CONSUMPTION POWER 180W 220W 270W AIR FLOW MAX 600m hr 900m hr 1200m hr C O O TAIWAN 9 ...

Отзывы: