Safety distance to combustible object and fi re prevention measures for
the surroundings
•
If the upper distance of at least 20cm (sides), 15cm (rear) and 100cm (top) is unavailable between
the appliance and flammable wall.
•
Install a heat insulating plate as shown in the illustration below.
•
Be sure to observe the precautions on installation to ensure compliance with the Fire Prevention
Ordinance. Insufficient clearance around the appliance may result in fire. Even if an inflammable wall
is covered with the object such as stainless steel plate, it is necessary to maintain the same distance as
required for combustible objects.
•
Do not refurbish the appliance’s surroundings after the installation (such as enclosing the appliance,
installation of hanging shelf). Such a refurbishment may not be compatible with the installation standards
or cause imperfect combustion or fire.
•
If the wall around the appliance is fl ammable (such as wooden wall)
•
Be sure to keep a distance of at least 20cm, 15cm and 100cm for sides, rear and top respectively.
(For RGA-408B, RGA-410B, RGA-408C, RGA-410C, an exhaust pipe with exhaust hood needs to be
installed above the appliance)
Material
Thickness
Caution
Steel plate
Stainless steel plate
0.6cm and above
0.6cm and above
Ensure a space at least 3cm and provide
adequate reinforcement to prevent harmful
deformation.
- 6 -
15cm and above
20cm and above
100cm and abo
ve
0cm and above
0cm and above
3cm and above
Lea
v
e
a gap
80cm and abo
ve
50cm and abo
ve
0cm and above
0cm and above
3cm and abo
ve
0cm and abo
ve
3cm and above
Contact your dealer or gas supplier for a heat insulating plate.
room and belo
w
when installing
e
x
haust hood
Heat insulating plate