Sensors and Safety Functions
•
Hot Water Delivery Thermistor:
Measures hot water temperature at the outlet valve (i.e. the ‘mixed’
temperature).
•
Heat Exchanger Thermistor:
Measures water temperature in the heat exchanger.
•
Flame Rod:
Monitors combustion characteristics inside the combustion chamber. If the flame fails, gas
supply is stopped.
•
Overheat Switch:
Situated on the heat exchanger, gas supply is stopped when water temperature
reaches 97ºC for a number of seconds.
•
Fusible Link:
Situated on the heat exchanger, electrical power supply is stopped if the temperature
exceeds 129ºC.
•
Water Pressure Relief Valve:
Safeguards the water circuit against excessive inlet pressure. Opens at
2060 kPa, closes at 1470 kPa.
•
Electrical Fuse:
(3A glass fuse) prevents against power surges.
•
Surge Protector:
prevents against over-current.
•
Boil Dry Prevention:
If water flow sensor detects no flow, gas supply is stopped.
•
Combustion Fan Speed Sensor:
In case of combustion fan defect (no rotation of fan blades) gas supply
is stopped.
•
Temperature Cutout:
If the delivered hot water temperature rises above the required delivery
temperature for a number of seconds, the gas supply is stopped.
Combustion Specifications
Refer to dataplate on the appliance.
Содержание REU-VR3237WG
Страница 13: ...Infinity REU VR3237WG HD250e REU VRM3237WC 8 Issue 1 19 05 09 Rinnai 6 Cutaway Diagram...
Страница 14: ...Infinity REU V3237WG HD250e REU VM3237WC 9 Issue 1 19 05 09 Rinnai 7 Operational Flow Chart...
Страница 15: ...Infinity REU V3237WG HD250e REU VM3237WC 10 Issue 1 19 05 09 Rinnai...
Страница 46: ...Infinity REU VR3237WG HD250e REU VRM3237WC 41 Issue 1 19 05 09 Rinnai REU V53237WG AK REU V5M3237WC 65 AK...
Страница 47: ...Infinity REU VR3237WG HD250e REU VRM3237WC 42 Issue 1 19 05 09 Rinnai REU V53237WG AK REU V5M3237WC 65 AK...
Страница 48: ...Infinity REU VR3237WG HD250e REU VRM3237WC 43 Issue 1 19 05 09 Rinnai REU V53237WG AK REU V5M3237WC 65 AK...