REU-VR1620WG / REU-VR1620WB / REU-VR1620WS / REU-VR2024WG
- 2 -
Issue 1 - 5/08/09 ©Rinnai
Rinnai model number
REU-V
R
2024W
G
Type of appliance
Temperature controlled continuous flow gas hot water system
Exhaust system
Fan Forced Flue
Installation
External
Dimensions
Width - 350 mm
Height - 530 mm
Depth - 194 mm
Weight
15 kilograms
Gas consumption (Min. / Max.)
REU-V1620WG / REU-V1620WB
Natural gas : Approx. 14 ~ 160 MJ/h
Propane gas : Approx. 14 ~ 160 MJ/h
Output (kW) (Maximum)
35.5 kW
Connections
Gas connection - R3/4 (20A)
Cold water connection - R 3/4 (20A)
Hot water connection - R 3/4 (20A)
Ignition system
Direct electronic ignition
Electrical consumption
Normal - 65 W
Standby - 2 W (with 1 water control)
Anti-frost protection - 100 W
Delivery temperatures
40°C, 42°C, 50°C, 55°C, 65°C, 75°C
(set by combination of dip switches on PCB)
Water flow control
Water flow sensor, electronic water flow control device
Maximum hot water capacity, raised @
25°C
20 L/min
Water pressure required to achieve
maximum hot water capacity
120 kPa
Maximum water flow
24 L/min
Maximum water flow, outlet temp < 60°C
L/min
Water pressure required to achieve
maximum water flow
160 kPa
Minimum water flow for operation
2.4 L/min
Power supply
Appliance - AC 240 Volts 50 Hz
Water controller - DC 12 Volts
Water controllers (optional)
- Wireless water controller only
installations
- Wired & Wireless Water Controller
Installations
A maximum of 4 water controllers can be fitted. Any combination of
deluxe, universal and wireless controllers can be used with the
following limitations:
Only ONE master controller can be installed. This can be a MC-100V,
a MC-91Q (when programmed as a mater controller) or a MC-502RC/
MC-503RC water controller.
Up to TWO BC-100V water controllers can be installed.
The FOURTH water controller in any installation MUST be a
MC-502RC / MC-503RC or a MC-91Q.
Water Controller Cable
Cables are supplied with water controllers. Alternatively, two core
sheathed (double insulated) flex with minimum cross sectional area of
0.5 m² may be used. Maximum individual cable runs should not
exceed 50 m.
Содержание REU-VR1620WB
Страница 16: ...REU VR1620WG REU VR1620WB REU VR1620WS REU VR2024WG 11 Issue 1 5 08 09 Rinnai REU VR2024...
Страница 17: ...REU VR1620WG REU VR1620WB REU VR1620WS REU VR2024WG 12 Issue 1 5 08 09 Rinnai 7 Operational Flow Chart...
Страница 48: ...REU VR1620WG REU VR1620WB REU VR1620WS REU VR2024WG 46 Issue 1 5 08 09 Rinnai...
Страница 49: ...REU VR1620WG REU VR1620WB REU VR1620WS REU VR2024WG 47 Issue 1 5 08 09 Rinnai...
Страница 50: ...REU VR1620WG REU VR1620WB REU VR1620WS REU VR2024WG 48 Issue 1 5 08 09 Rinnai...
Страница 51: ...REU VR1620WG REU VR1620WB REU VR1620WS REU VR2024WG 49 Issue 1 5 08 09 Rinnai REU VR2024WG...
Страница 52: ...REU VR1620WG REU VR1620WB REU VR1620WS REU VR2024WG 50 Issue 1 5 08 09 Rinnai...
Страница 53: ...REU VR1620WG REU VR1620WB REU VR1620WS REU VR2024WG 51 Issue 1 5 08 09 Rinnai...
Страница 54: ...REU VR1620WG REU VR1620WB REU VR1620WS REU VR2024WG 52 Issue 1 5 08 09 Rinnai...