background image

Gas Pressure Setting

NOTE: For additional installation and commissioning information 

refer to the Operation and Installation Manual.

APPLIANCE OPERATING PRESSURES

Water Inlet Max is 150 PSI

Ensure gas pressure check under Commissioning has been

completed first! The regulator is electronically controlled and

factory pre-set. Under normal circumstances it does not require

adjustment during installation. Make adjustments only if the unit is

not operating correctly and all other possible causes for incorrect

operation have been eliminated.

1. Turn OFF the gas supply.

2. Turn OFF the 120 V power supply.

3. Remove the front panel from the appliance.

4. Check the gas type using the data plate on the side of the unit.

If using a spare PC board, check that the gas type switches are

in the correct position (dip switch 1: ON for natural gas, NG, and 

OFF for propane, LPG). See dip switch settings section below. (ON 

is towards the right and OFF is towards the left.)

5. Attach the pressure gauge to the burner test point, located on

the gas control (Fig. 2).

6. Turn ON the gas supply.

7. Turn ON the 120 V power supply.

8. Turn the unit ON with the controller. Select the maximum delivery

temperature and open an available hot water fixture. Leave the 

fixture on until all gas pressure setting is complete

9. When the red “In Use” light turns on, set the unit to “Forced Low”

combustion by setting No. 7 dip switch to ON (Fig. 3).

10. Check the burner test point pressure.

11. Remove the rubber access plug and adjust the regulator screw

on the modulating valve (Fig. 4) as required in Table 1. Replace the 

rubber access plug.

12. Set the unit to “Forced High” combustion by setting both No. 7

and No. 8 dip switches to ON (Fig. 5). Ensure maximum water flow.

13. Check the burner test point pressure.

14. Adjust the high pressure potentiometer (POT) on the PC board

as required to the pressure shown in Table 1.

15. Return the unit to normal operation by setting dip switches 7

and 8 back to OFF (Fig. 6). Close all water taps.

16. Turn OFF the gas supply and 120 V power supply.

17. Remove the pressure gauge and install sealing screw.

18. Turn ON the gas supply and 120 V power supply.

19. Operate the unit and check for gas leaks at the test point.

20. Install the front panel.

NOTE: For additional installation and commissioning information 

refer to the Operation and Installation Manual.

Commissioning

With all gas appliances in operation at maximum gas rate, the

flowing inlet pressure at the incoming test point on the Rinnai

water heater should read 4" W.C. - 10.5" W.C. on natural gas

and 8" W.C. - 13.5" W.C. on propane gas. If the pressure is

lower, the gas supply is inadequate and the unit will not operate

to specification. Check the gas meter regulator and pipework for

correct operation/sizing and correct as required.

Gas Inlet Min/Max

Forced Low

Forced High

Nat. G.

LPG

Nat. G.

LPG

Nat. G.

LPG

4" W.C. / 

10.5" W.C.

8" W.C. / 

13.5" W.C.

1.10

" W.C. 1.

23

" W.C. 2.

8

" W.C.

 3.0

"

W

 .

C

This appliance must be installed, serviced and removed by a 

trained and qualified person. During pressure testing of the 

consumer piping, ensure gas valve is turned off before unit is shut 

off. Failure to do so may result in serious injury to yourself or 

damage to the unit.

Temperature 

Display

Indicates 

temperature 

setting or flashes 

error code.

In Use Indicator

Indicates the 

water heater is in 

a recovery mode.

Temperature 

Selector

ON / OFF 

Button

Table 1

RH180 (REU-VA1320WF-US) 

Technical Data Sheet

Hybrid Tank-Tankless Water Heater

Содержание REU-VA1320WF-US

Страница 1: ...d High combustion by setting both No 7 and No 8 dip switches to ON Fig 5 Ensure maximum water flow 13 Check the burner test point pressure 14 Adjust the high pressure potentiometer POT on the PC board as required to the pressure shown in Table 1 15 Return the unit to normal operation by setting dip switches 7 and 8 back to OFF Fig 6 Close all water taps 16 Turn OFF the gas supply and 120 V power s...

Страница 2: ...fuse Remove the fuse and check continuity through it If you have continuity through the fuseB then it is good Otherwise the fuse is blown and Wire Color Voltage Resistance Connector Pin s Tank Temperature Thermistor White Yellow at the PCB White White N A See Chart Above A2 A 3 A 4 Heat Exchanger Temperature Thermistor Brown Yellow at the PCB White White N A See Chart Above A3 A 7 A 8 Burner Senso...

Страница 3: ...SMALL LARGE MODUL ATING SOLENOID VALVE FLAME ROD POV F3 O O Y THERMALFUSES W W F1 OVERHEAT SWITCH A6 R R R BL P GY BR O Y W P BL R BK W AC120V AC120V HOT NEUTRAL HOT GROUND FUSE 5A SURGE PROTECTOR 3 1 G Y 1 3 I 1 GND I 2 W BK BR BL GND G Y IG ELECTRODE SPARK IGNITER G Y BK W W BK G Y GND 1 3 1 2 1 2 6 1 4 14 P PUMP COS CO SENSOR OPERATION UNIT P GY R W Y BK R W Y BK R R BK Y W BL BK R P Y Y OO O O...

Страница 4: ... identified the area as safe and all flammable vapors have been evacuated the units can be rest by unplugging the unit then plugging back in If FE continues to flash after area is determined safe contact a qualified service technician 16 Over Temperature Warning Check gas type of unit and ensure it matches gas type being used Check for restrictions in air flow around unit Check for foreign materia...

Страница 5: ...05 801 006 015 802 801 017 016 001 002 010 011 012 013 014 003 004 A A B B C C 725 120 125 132 131 121 727 127 726 827 828 111 110 113 114 116 103 803 115 112 117 130 133 750 825 730 804 126 134 135 123 122 724 ...

Страница 6: ...D D 405 406 751 806 703 704 805 102 101 701 705 700 402 401 404 824 101 100 821 708 702 823 400 408 409 826 410 822 124 723 722 714 712 711 729 715 716 807 825 728 713 720 721 710 ...

Страница 7: ...034 035 037 038 039 040 041 042 033 044 048 047 049 050 051 046 045 046 052 055 055 052 Pump Configurations 043 ...

Страница 8: ... Tank Thermistor 105000089 1 037 Drain Valve 107000118 1 132 Fan Casing Assembly 108000033 1 1 4 0 1 1 D 8 M r o s n e S R M 9 2 7 038 Diptube 107000119 1 133 Fan Motor Packing 109000106 1 730 Easy Connection 105000090 1 039 Thermistor Bracket 109000368 1 134 Fan Motor Bracket 109000107 1 750 CO Sensor 105000091 1 040 Shoe Horse Grommet 109000369 1 135 Noise Filter Ass y 109000108 1 751 FV Sensor ...

Отзывы: