GAS PRESSURE SETTING 

The  working  gas  pressure  on  the  water  heater  is  electronically  controlled  and  factory  set.  
Under  normal  circumstances  it 

does  not 

require  adjustment  during  installation.  The 

pressure should be checked when the unit is installed and each time it is serviced to ensure 
that it is correct.  

Contact Rinnai  before attempting to alter the gas pressure if you are 

unsure of what to do. Incorrect adjustment can void the warranty. 

 
1.  Turn 'OFF' the gas supply. 

 

2.  Turn 'OFF' 230V power supply. 

 

3.  Remove the front cover from the appliance (4 screws). 

 

4. Check gas type using the dataplate on the side of the casing and confirm the dip switches 

(Fig. 1) are in the correct position for the type of gas (Nat. or LPG)* you are using (see 

page 40

). 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

5.  Attach pressure gauge to burner test point (Fig. 2). 

 

6.  Turn 'ON' the gas supply. 

 

7.  Turn 'ON' 230V power supply. 

 

8.  If remote controllers are fitted, turn the unit 'ON' at the controller and select a maximum 

delivery temperature. 

 

9.  Open  hot  water  taps  fully  to  reach  max  flowrate. 

(CAUTION:  Ensure  building 

occupants do not have access to hot water outlets during this procedure.)  

If there 

is  not  enough  water  flowing,  the  water  heater  might  shut  off  or  damage  due  to 
overheating. 

*  Simply  changing  the  position  of  the  dip  switches  will  not  convert  the  unit 
from one gas type to the other. The conversion procedure requires a change of  
injector manifold. 
Contact Rinnai if you want to convert the appliance to a different gas family. 

NOTE

Fig. 1 

Fig. 2 

Содержание REU-KBM3237FFUDHD-E

Страница 1: ...Service Manual REU KBM3237FFUDHD E HDC 1600i Low NOx REU KBM3237WDHD E HDC 1600e Low NOx Continuous Flow Water Heater...

Страница 2: ...to Service this appliance if you are not qualified This can void the warranty This manual must be read in its entirety before Servicing the appliance If you are unsure of any point contact Rinnai UK...

Страница 3: ...3 Service Information Page 4 Service Procedure Page 5 6 Gas Pressure Setting Page 7 8 Dip Switch Setting Page 9 Temperature Setting Page 10 Contact Information Page 12 CONTENTS...

Страница 4: ...the appliance continues to operate with damaged gaskets or seals this could affect the performance or correct safe operation of the appliance Servicing is required to maintain the appliances warranty...

Страница 5: ...teps below Isolate the appliance by the plug or fused spur and isolate the gas supply Ensure the appliance is cool enough for the Electrode Kit to be removed Remove the Spark Electrode Ionisation Elec...

Страница 6: ...et With the appliance in Normal Operation mode you can carry out a Flue Gas Analysis if you wish to do so Please see the below table for normal operating parameters If you have concerns over any readi...

Страница 7: ...dip switches Fig 1 are in the correct position for the type of gas Nat or LPG you are using see page 40 5 Attach pressure gauge to burner test point Fig 2 6 Turn ON the gas supply 7 Turn ON 230V power...

Страница 8: ...OFF position Fig 5 17 Close hot water taps and turn OFF the gas supply and 230V power supply 18 Remove pressure gauge and replace sealing screw Turn ON the gas supply and power 19 Operate unit and ch...

Страница 9: ...ction indicates position of dip switch OFF ON OFF ON OFF ON Model Type FF Long FF Short W FF Long Common vent1 factory setting factory setting Common vent2 FE Off On Off On Off On Off On SW1 1 SW1 1 S...

Страница 10: ...10 TEMPERATURE SETTING...

Страница 11: ...11...

Страница 12: ...12 UK LTD 9 Christleton Court Manor Park Runcorn Cheshire WA7 1ST Tel 01928 595959 Fax 01928 531880 E mail engineer rinnaiuk com Web www rinnaiuk com CONTACT...

Отзывы: