background image

 

2

 

Rinnai Corporation Conversion Manual

   

Safety Symbols

 

Indicates an imminently hazardous situation which, if not avoided, will result in death or 

serious injury.

 

Indicates a potentially hazardous situation which, if not avoided, could result in death or 

serious injury.

 

Indicates a potentially hazardous situation which, if not avoided, could result in minor or 

moderate injury.  It may also be used to alert against unsafe practices.

 

This is the safety alert symbol.  This symbol alerts you to potential hazards that can kill or hurt you and 

others.

 

     

DANGER

 

     

CAUTION

 

     

WARNING

 

 

Technical Data

 ........................... 

2

-

3

 

Parts List

 ....................................... 

3

 

Gas Conversion Procedure

 ........... 

4

 

Adjust Gas Pressure Settings

 ....... 

5

 

Check Operation

 ........................... 

6

 

Operating Instructions

 ................... 

7

 

 
 
 

FOR INSTALLATIONS IN CANADA, THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH 

THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE 

WITH THE REQUIREMENTS OF THE 

CGA

-

B149.1, NATURAL GAS AND PROPANE INSTALLATION CODE.

 

The appliance must be installed in accordance with:

 

• 

local codes or, in the absence of local codes, the 

National Fuel Gas Code, ANSI Z223.1/

NFPA 54 

and/or 

CSA B149.1, Natural Gas and Propane Installation Code.

 

• 

the 

Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 

and/or 

CAN/CSA Z240 MH Series, Mobile Homes, Series M86.

 

Natural Gas (Gaz Naturel) 

 

Minimum 

-

 Maximum supply gas pressure

 

(Pression de gaz d'alimentation 

-

 Minimum 

-

 Maximum)

 

MIN 4.5 in (114 mm) W.C.

 

 MAX 10.5 in (267 mm) W.C.

 

Propane Gas (Gaz propane)

 

Minimum 

-

 Maximum supply gas pressure

 

(Pression de gaz d'alimentation 

-

 Minimum 

-

 Maximum)

 

MIN 8 in (203 mm) W.C.

 

MAX 13.5 in (343 mm) W.C.

 

Technical Data (Données Techniques)

 

Содержание REU-AM1620WD-US

Страница 1: ...onal injury or death The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is c...

Страница 2: ...ONS IN CANADA THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CGA B149 1 NATURA...

Страница 3: ...l Mod le To Gas type au gaz Kit Number Numero de kit Kit Contents Contenu de kit Conversion Rating Plate Plaque de Conversion Gas Manifold Gaz collecteur Damper Amortisseur Instruction Label tiquette...

Страница 4: ...k O Ring is intact on the gas control valve see Figure 2 and the gasket is intact on the replacement gas manifold Position the new gas type manifold in place 9 Install the gas manifold with the 2 mach...

Страница 5: ...water lines These areas become very hot and could cause burns CAUTION Do not touch any other areas on the PC board besides the SW switches while power is supplied to the appliance Parts of the PC boar...

Страница 6: ...omatic ignition system When the main burner has lit the combustion lamp will glow red and the spark will stop Check Operation Visual Inspection of Flame Check that the burner flames are operating norm...

Страница 7: ...ellement Faites inspecter l appareil par un technicien qualifi et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau TO TURN OFF GAS TO APPLIANCE 1 Turn off a...

Страница 8: ...100000566 01 7 2018 U340 1922...