12 

 

 |   

A-Series CFWH installation guide 01-18

PCB interface and dip switch settings

The PCB interface and dip switch settings must only be changed by a licensed 
gasfitter. They have been provided as there may be a requirement to change the 
temperature of the water delivered from the water heater or change the dip switch 
settings if fitting a flue diverter.

Care must be taken when changing the temperature or dip switch settings as they can be 
easily switched or bumped into the wrong position. Fully check the operation of the water 
heater before leaving including the temperature of the water delivered.

The cover of the water heater will need to be removed to carry out this operation. As this will 
expose live mains voltage wiring 

please disconnect the power supply before removing the 

front cover

.

We wish to draw your attention to the requirements of the New Zealand Building Code and 
compliance document G12. This requires that water delivered to sanitary fixtures be no more 
than 55 °C. Increasing the water heater set temperature will require that you protect all sanitary 
fixtures to which the appliance is plumbed with suitable tempering valves or something similar.

Rinnai will accept no liability for issues arising out of the use of this information.

If you have any doubts about the performance of the water heater, please contact Rinnai by 
phoning 0800 RINNAI (0800 746 624).

The following information details settings for the Rinnai INFINITY A-Series models only. They are 
not applicable for other models.

Basic operation of the PCB interface

•  To place the PCB into programming mode press PB2 until the LED digital display shows 

1

noting that the current set value will be displayed shortly afterwards.  

•  To alter a value press PB4, each press of the button will select the next available value. 

•  To change to another menu, press PB3, each press of the button will select the next available 

menu. 

•  To exit the programming mode and save the selected settings press PB2 until the LED display 

goes blank.

Note:

•  If no buttons are pressed the PCB will automatically exit programming mode after 10 mins.
•  Exiting programming mode sets the value last viewed as the current value.

WARNING

Содержание REU-A1620WG-ZK

Страница 1: ...ow water heaters Installation guide INFINITY A26 INFINITY A24 INFINITY A20 INFINITY A16 REU A1620WG ZK REU A2024WG ZK REU A2426WG ZK REU A2626WG ZK The Rinnai INFINITY A Series models are not suitable...

Страница 2: ...person being in New Zealand a licensed gasfitter in accordance with these instructions and all applicable local rules and regulations Warning Improper installation adjustment alteration service and m...

Страница 3: ...General installation information 5 Water delivery temperature 6 Connections and fittings 7 Dimensions mm 8 Commissioning 10 PCB interface and dip switch settings 12 Flue diverter dip switch changes 14...

Страница 4: ...en the water heater and the outlets is considerable a flow and return system can be used to minimise the waiting time for hot water delivery Alternatively multiple appliances can be strategically plac...

Страница 5: ...he gas meter and regulator must be specified for this gas rate An approved sizing chart such as the one in AS NZS 5601 should be used Refer p 7 for model specific gas consumption details Water pipe si...

Страница 6: ...home or similar facility as defined in AS NZS 3500 4 a Temperature Limiting Device TLD such as a tempering valve may be required even if the appliance is set to 55 C or less For these types of applic...

Страница 7: ...ns Isolation valves MUST NOT be fitted directly to the appliance It may be necessary to fit a temperature limiting device for delivery to areas used primarily for the purposes of personal hygiene refe...

Страница 8: ...48 9 16 5 7 34 270 351 330 223 212 531 498 16 5 15 48 9 16 5 270 34 7 The basic dimensions height width and depth are the same The difference between the models are the dimensions and position of the...

Страница 9: ...A Series CFWH installation guide 01 18 9 171 9 1 15 29 5 495 8 571 180 160 80 5 5 x 24 long hole 5 5 x 24 long hole 13 hole 41 34 31 489 2 541 2 557 2...

Страница 10: ...en eliminated Inlet supply pressure to the appliance MUST BE checked and set within the operating parameters of the appliance in all instances If the appliance can not be adjusted to perform correctly...

Страница 11: ...old water inlet filter Inspect and clean the water inlet filter This may need to be repeated to ensure the filter remains clear especially on new installations Short video http rinnai co nz 006 If you...

Страница 12: ...C Increasing the water heater set temperature will require that you protect all sanitary fixtures to which the appliance is plumbed with suitable tempering valves or something similar Rinnai will acc...

Страница 13: ...remain set in the OFF position SW2 and SW4 are not used and MUST remain set in the OFF position PB1 PB2 PB3 PB4 PB5 SW1 SW2 SW3 SW4 Menu Menu description Value A b C d E F H J 1 Gas type ULPG NG N A N...

Страница 14: ...nd SW3 of the DipSW must be set to the ON position 1 2 3 4 ON SW1 OFF SW2 OFF SW3 OFF SW4 OFF 1 2 3 4 ON SW1 ON SW2 OFF SW3 ON SW4 OFF Default dip switch settings as they are ex factory Dip switch set...

Страница 15: ...hrough five below to terminate the cables to the water heater Connecting three or four communication cables To connect three or four cables separate all the cables to be fitted into pairs A A A When t...

Страница 16: ...Rinnai co nz Experience our innovation 0800 746 624 http www youtube com rinnainz a touch of magic U340 1336 01...

Отзывы: