U S A G E   A N D   I N S T A L L A T I O N   M U S T S

1.

Read these rules and the instructions carefully. Check all local codes. Failure to follow these could cause a
malfunction of the heater resulting in death, serious bodily injury and/or property damage.

2.

This heater is designed for use only with one type of gas, either L.P.G. or Natural Gas. Make sure that the type of
gas to be supplied to this unit matches that shown on the rating plate on the heater. This unit is not convertible.

3.

WARNING

: Any change to this heater or its controls can be dangerous.

4.

If a gas leak is suspected, turn heater off, turn gas supply valve off at regulator or appliance connecter valve. Open
windows to ventilate area immediately and contact your dealer or gas company.

5.

Installation and repair should be done by a qualified service person. Heater should be inspected before use and at
least annually by a professional service person. More frequent cleaning may be required due to excessive lint from
carpeting, bedding material, etc. It is imperative that control compartment, burners and circulating air passageways
be kept clean.

6.

Keep area near the heater clear and free from combustible materials, gasoline and other flammable vapors and
liquids.

7.

Due to its high temperature, the heater should be located out of traffic and away from furniture and draperies.

8.

Do not place clothing or flammable material on or near the heater.

9.

Any safety panel or guard removed for servicing must be replaced prior to operating the heater.

10.

An unvented gas heater will increase the amount of humidity in the room.

11.

This heater is intended for space heating purposes only. Do not use for other purposes such as drying clothes or
baking paints.

12.

Do not touch the outlet area while the heater is in use. To avoid burns, do not move the heater during use and
avoid touching the heater just after turning off.

13.

Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid
burns or clothing ignition.

14.

Young children should be carefully supervised when they are in the same room with the heater.

15.

L.P.G containers must not be installed indoors.

16.

Do not install in a windy area such as facing a window or a door leading to the outside.

17.

Do not use this room heater if any part has been under water. Immediately call a qualified service technician to
inspect the room heater and to replace any part of the control system and any gas control which has been under
water.

18.

Carpet lint or cigarette smoke may pass through the heater, discolor, and be deposited into the room.

19.

This unit discharges a large volume of warm air at a low level to provide even heat distribution. If the air in the
room contains cooking vapors, cigarette smoke, and if used on carpet, the surface in front of unit is subject to
discoloration. Some carpets contain dyes which can be effected by warm air flow and could discolor. To aid in
prevention of discoloration, place a mat under the unit to extend to the front 30 “.

Содержание RCE-229A

Страница 1: ...OSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE INSTALLER MUST LEAVE MANUAL WITH UNIT AFTER INSTALLATION OWNER RETAIN THIS MANUAL SAFELY FOR FUTURE REFERENCE WHAT TO DO IF YOU...

Страница 2: ...3 IMPORTANT POINTS 4 SAFETY POINTS 5 USAGE AND INSTALLATION MUSTS 7 INSTALLATION INSTRUCTIONS 8 OPERATING INSTRUCTION PLATE 11 ADDITIONAL CUSTOMER OPERATING INFORMATION 12 MAINTENANCE SERVICE 17 TROU...

Страница 3: ...e ignition procedure Oxygen Depletion Safety Device If the oxygen level in the room drops below a pre set limit this device cuts the gas supply off to the heater If the oxygen depletion device operate...

Страница 4: ...In some cases curtains may need restraining It must also be 2 50mm clear of walls 5 This appliance is not designed to be built in 6 If you move check the gas type in the area where you are moving to T...

Страница 5: ...d irritate eyes and sinuses Do not spray aerosols near this heater while it is in use Many aerosols contain butane gas and can be a fire hazard Use of aerosols paint polishes etc while this heater is...

Страница 6: ...away from flammable materials Combustible materials must not be placed where the heater could ignite them Do not place articles in front of the hot air discharge Do not allow children to put articles...

Страница 7: ...or near the heater 9 Any safety panel or guard removed for servicing must be replaced prior to operating the heater 10 An unvented gas heater will increase the amount of humidity in the room 11 This h...

Страница 8: ...construction unless provisions are provided for adequate combustion and ventilation air The National Fuel Gas Code ANSI Z223 1 defines a confined space as a space whose volume is less than 50 cubic f...

Страница 9: ...e heater shall be installed on a metal or wood panel extending the full width and depth of the heater 3 Adequate clearances for accessibility for purposes of servicing and proper operation must be pro...

Страница 10: ...leak test solution is noncorrosive 7 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures...

Страница 11: ...floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your b...

Страница 12: ...ation is currently displayed on the LED display ECONOMY INDICATOR I n d i c a t e s t h a t t h e E c o n o m y m o d e i s i n o p e r a t i o n COMBUSTION INDICATOR Indicates that the burner is alig...

Страница 13: ...g the appliance while the convection fan is running DO NOT turn heater off by unplugging at the power point The convection fan will continue to run until the appliance cools ROOM TEMPERATURE ADJUSTMEN...

Страница 14: ...if the heater is under capacity for the room size FUNCTION LOCK The Function Lock will help to prevent accidental operation as well as small children from altering the controls To operate the Function...

Страница 15: ...nce and run the heater for 60 minutes after which the heater will remain in the ON Timer standby mode OFF TIMER STOPS AFTER 1 HOUR Five minutes before the finish of the OFF Timer the OFF Timer indicat...

Страница 16: ...appliance will remain in standby mode 3 The heater will operate after reaching the end of the preset time ON Combustion Indicator glows red The heater will operate at the preset temperature selected i...

Страница 17: ...rocedures of heater are as follows 1 Turn heater off Unplug electric cord and allow to cool for one hour 2 Remove the two 2 screws that hold the louver and two 2 screws at the bottom of the left and r...

Страница 18: ...stored Initial Installation Air in Gas Pipe Purge air installer Room too Large Check with retailer Dust on the Air Filter Clean the air filter weekly Louver Obstructed Clean obstruction Air Filter Blo...

Страница 19: ...servicing If any of the original wire as supplied with the appliance must be replaced it must be replaced with a wire of at least a 194 F temperature rating WARNING Electrical Grounding Instructions...

Страница 20: ...Model RCE 229A www rinnaina com 2 0 S C H E M A T I C D R A W I N G S Cabinet Exploded View...

Страница 21: ...Model RCE 229A 800 621 9419 2 1 S C H E M A T I C D R A W I N G S Gas Valve Burner Assembly Exploded View...

Страница 22: ...Model RCE 229A www rinnaina com 2 2 S C H E M A T I C D R A W I N G S Fan Blower Assembly Exploded View...

Страница 23: ...Model RCE 229A 800 621 9419 2 3 S C H E M A T I C D R A W I N G S Electrical Wiring Exploded View...

Страница 24: ...TION PIPE ASS Y RC 229 512 1 104 2 SCREW ZHAA0406SZ 2 105 1 INJECTOR HOLDER RC 208 22 1 105 2 SCREW ZFAB0410SZ 2 INJECTOR RC 208 11 2 1 20 1 NG INJECTOR RC 208 11 1 0 90 1 LPG 107 1 DAMPER RC 208 23 2...

Страница 25: ...96 1 137 1 CONNECTION PIPE FIXER RC 208 21 1 137 2 SCREW ZFAB0408SZ 1 138 1 OVER HEAT SWITCH ES 01183 1 138 2 SCREW CP 30518 1 2 139 CIRCUIT BOARD SPACER CP 90436 3 4 140 1 OUTLET RC 229 511 1 140 2...

Страница 26: ...SZ 1 710 1 OVER HEAT THERMISTOR RC 241 70 1 710 2 SCREW ZFAB0408SZ 1 711 1 OPERATION P C B RC 229 517 1 711 2 SCREW ZGAA0308SZ 5 800 OWNER S INFORMATION MANUAL RC 229 521 1 RATING PLATE RC 229 527 1 1...

Страница 27: ...e ability to check its own operation continuously If a fault occurs an Error Message will flash on the Digital Display of the control panel This assists with diagnosing the fault and may enable you to...

Страница 28: ...yimpliedwarrantiesofmerchantabilityandfitnessapplicabletotheequipmentarelimitedindurationtotheperiodofcoverageofthisexpress written warranty Some states do not allow limitations on how long an implied...

Отзывы: