R98LSe (VA3237W)
Rinnai Corporation
• 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
Simulation feed forward and feedback
MC-91-1US (included)
Deluxe controller: MC-100V-1US (optional)
Bathroom controller: BC-100V-1US (optional)
Wireless controller: MC-502RC-1US-MS (optional)
MCC-91-1US (for commercial applications)
Non-polarized two-core cable, minimum 22 AWG
•
Flame failure - Flame Rod
•
Boiling protection
•
Combustion fan rpm check
•
Over current - glass fuse (3 amp)
•
Top of heater - 12 inches
•
Front (Panel) - 24 inches
•
Front (Exhaust) - 24 inches
•
Top of heater - 2 inches
•
Front (Panel) - 0 inches *
•
Front (Exhaust) - 24 inches
Natural Gas: min 5” W.C.
max 10.5” W.C.
Propane Gas: min 8” W.C.
max 13.5” W.C.
Natural Gas: high fire 2.8” W.C. low fire 0.65” W.C.
Propane Gas: high fire 3.8” W.C. low fire 0.80” W.C.
Meets California and Texas NOx Emission Rules
Heat exchanger: 12 years* for residential and 5 years* for
commercial and hydronic applications; (10 years* if used with the
Rinnai Hydronic Air Handler); all other parts 5 years*; labor 1 year;
(* 3 years if used as a circulating water heater within a circulation
loop, when the water heater is in series with a circulation system
and all circulating water flows through the water heater)
DIMENSIONS
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
WEIGHT: 55 LBS
Water Temperature Control
Controller
Controller Cable
Safety Devices
Clearances from Combustibles
Clearances from Non-combustibles
* 24 inches required for serviceability
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx
Warranty
98° - 140° F
98° - 185° F
•
Remaining flame (OHS)
•
Thermal fuse
•
Automatic frost protection
•
Back of heater - 0 inches
•
Bottom of heater - 12 inches
•
Sides of heater - 6 inches
•
Back of heater - 0 inches
•
Bottom of heater - 2 inches
•
Sides of heater - 1/8 inch