background image

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

0

25

50

75

100

125

150

delta T - Temperature Rise (ºF) 

 Water Flo

w

 (gpm)

 

R75LSi (VA2528FFUD)    

Type of Appliance 

Rinnai Model Number 

Operation / Exhaust System  

Minimum/Maximum Gas Rate (Input) 

Electrical 

 
Electrical Consumption 

 
 
Ignition System 

Hot Water Capacity 

Temperature 

 
 
Temperature (without remote)  

Approved Gas Types 

Installation 

Energy Factor 

Thermal Efficiency 

Service Connections 

 
 
Water Flow Control 

Minimum/Maximum Water Supply Pressure 

Temperature controlled, continuous flow, gas hot water system 

REU-VA2528FFUD(A)-UC 

Forced combustion / Direct vent 

15,000 - 180,000 BTU/h (Natural Gas and Propane)  

Appliance: 

 

 

AC 120 Volts - 60 Hz 

Controller: 

  DC 

12 

Volts 

Normal 

   65 

watts 

Standby   2.0 

watts 

Anti-frost protection 

 

100 watts 

Direct electronic ignition 

0.6 to 7.5 GPM (35° F rise) 

98° - 120° F  (factory default)  Maximum temperature is selectable at 
120° F or at 140° F;  98° - 160° F available with the MCC-91 
controller for commercial and hydronic applications 

120° F (factory default) 

Natural or Propane (ensure unit matches gas type) 

Indoor only 

Natural Gas: 0.82 

 

Propane: 0.82 

Natural Gas: 84% 

 

Propane: 84% 

Gas supply: 3/4 inch MNPT 
Cold water inlet: 3/4 inch MNPT 
Hot water outlet: 3/4 inch MNPT 

Water flow sensor, electronic water control device and fixed by-pass 

20 - 150 PSI (recommended 30-80 PSI for maximum performance) 

© 2008 Rinnai Corporation 

R75LSi SP                         8/2008 

FLOW TABLE 

Отзывы: