background image

Page 1

POLOCOOL Portable Room Air Conditioner 

 

Operation & Installation Manual

Models:

REFRIGERANT

R290

EX10C 

by

Содержание PoloCool EX10C

Страница 1: ...Page 1 POLOCOOL Portable Room Air Conditioner Operation Installation Manual Models REFRIGERANT R290 EX10C by ...

Страница 2: ...in accordance with the manufacturer s instructions Before proceeding with the operation of your new Rinnai Portable Room Air Conditioner please read this manual thoroughly and gain a full understanding of the requirements features and operation of your new appliance REFRIGERANT R290 ...

Страница 3: ... Hose Inlet Hose Outlet and Window Slider 16 Installation 16 Mounting of Assembled Air Exhaust Hose 17 Window Slider Installation 18 Description of the Control Panel 19 Operating Instructions 19 Operating from the Control Panel 20 Description of the Remote Control 22 Operating from the Remote Control 22 Operating the Remote Control 23 Timer 24 Self Diagnosis 25 Continuous Drainage 26 Water Drainag...

Страница 4: ...mote control y Do not connect to multiple power outlets on extension leads y Do not rest hot or heavy objects on the appliance y Always unplug the unit from the power outlet before cleaning or maintenance operations for example filter cleaning y Do not place the air conditioner or plastic window slider in direct sunlight y For maximum cooling efficiency keep the exhaust hose as short and as free o...

Страница 5: ...nt of the unit The maximum current is indicated on the nameplate located on unit have a qualified electrician install the proper earthed wall socket Install the unit on a flat sturdy surface Failure to do so could result in damage or excessive noise and vibration The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards Do not modify the length of the pow...

Страница 6: ...ised around the unit at all times be applicable for other countries except the European Countries If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Prior to cleaning or other maintenance the appliance must be disconnected from the supply mains Do not remove any fixed covers Never use this appliance if i...

Страница 7: ...ug Do not use hazardous chemicals to clean or come into contact with the unit Do not use the unit in the presence of inflammable substances or vapour such as alcohol insecticides petrol etc Always transport your air conditioner in a vertical position and stand on a stable level surface during use Always contact a qualified person to carry out repairs If the damaged power supply cord must be replac...

Страница 8: ...to be charged For specific information on the type of gas and the amount please refer to the relevant label on the unit itself Compliance with national gas regulations shall be observed Keep ventilation openings clear of obstruction The appliance shall be stored so as to prevent mechanical damage from occurring A warning that the appliance shall be stored in a well ventilated area where the room s...

Страница 9: ...lammable material 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants i e non sparking adequately sealed or intrinsically safe 5 Presence of fire exti...

Страница 10: ...ed components 1 During repairs to sealed components all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous sit...

Страница 11: ...ircuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to Remove refrigerant Purge the circuit with inert gas Evacuate Purge again with inert gas Open the circuit by cutting or brazing The refrigerant charge shall be recovered into the...

Страница 12: ...orking order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant Waste Transfer Note arranged Do not mix refrigerants in recovery units and especially no...

Страница 13: ...ture the fan continues operating and the compressor switches on and off to maintain the set temperature within the room y For maximum cooling output keep the exhaust hose as short and as straight as possible Minimise bends which can reduce the maximum cooling capacity of the air conditioner Elevate the air conditioner if necessary y Make sure the air intake and outlet grills are unobstructed y Cle...

Страница 14: ...e and packaging and released for transportation without known damage Upon receipt inspect the exterior for evidence of rough handling in shipment Ensure that the appliance is labelled correctly for the gas and electrical supply and or other services it is intended to be connected to For safety and warranty purposes appliances that may be damaged or incorrect MUST NOT be installed or operated under...

Страница 15: ...Page 15 Description Description of each part and function ...

Страница 16: ...d each end of the exhaust hose by about 10cm and attach the hose inlet and hose outlet to opposite ends by rotating the inlet outlet in a counter clockwise direction approximately 3 to 4 turns making sure that the hose wire is well threaded into the hose inlet and outlet The hose inlet and outlet cannot be installed unless the hose ends have been fully extended Clip the hose outlet into the window...

Страница 17: ...Page 17 Installation Instructions Mounting of Assembled Air Exhaust Hose ...

Страница 18: ...Page 18 Installation Instructions Window Slider Installation ...

Страница 19: ...Page 19 Operating Instructions Description of the Control Panel Operating Instructions ...

Страница 20: ...Page 20 Operating Instructions Operating from the Control Panel ...

Страница 21: ...er of times until the symbol appears Select the required fan speed by pressing the FAN button Three speeds are available High maximum speed for maximum fan power Medium speed reduces noise levels but still maintains a good level of comfort Low speed for silent operation Swing function Using this function will cause the air direction louvres to swing automatically directing the air flow left and ri...

Страница 22: ...OFF sleep function 15 SWING button Press this button to switch ON OFF the automatic swing function CORRECT USE Point the remote control at the receiver on the appliance The remote control must be no more than 7 metres away from the appliance without obstacles between the remote control and the receiver The remote control must be handled with extreme care Do not drop it or expose it to direct sunli...

Страница 23: ...Y mode Fan speed cannot be adjusted and is always set to low under this function TO SET 1 Select the desired mode of operation COOL or DRY 2 Press the SLEEP button sleep icon will appear on the display and the remote which will indicate the unit is set in SLEEP function 3 In SLEEP function if the unit is running in COOL mode after each hour the set temperature is increased by 1 C this happens for ...

Страница 24: ...ress the TIMER button the remote handset will display the time icon and ON next to it 4 Press the TIMER button once the clock display will come up and continue to flash next to the ON time icon 5 Set the time interval after which you want the unit to be turned ON using the UP DOWN button Gi 6 Once the selected time interval is set press theTIMERbutton again to storethe time interval in the memory ...

Страница 25: ...Page 25 Self Diagnosis Remote Control ...

Страница 26: ... and drain the water onto the ground The water tank is considered sufficiently drained when no more water flows from the drain outlet Restart the air conditioner by pressing the on off button Ensure that the unit is in COOL or DRY mode The compressor will start approximately 3 minutes after the unit is switched on NOTE To completely drain all water from the water tank tilt the unit by lifting it s...

Страница 27: ...Page 27 Cleaning Maintenance Maintenance ...

Страница 28: ...Page 28 Troubleshooting Troubleshooting ...

Страница 29: ... Normal Business Hours means 8 30am to 5 00pm Monday to Friday excluding public holidays 7 Operating Installation Instructions means the user manual or other documentation which provides detailed instructions on the proper operation and maintenance of the Product 8 Other Applications means any Product used for purposes other than Residential Light Commercial Applications OtherApplications may incl...

Страница 30: ...r or replacement shall be performed during Normal Business Hours by anAuthorised Service Representative Repair by persons other than anAuthorised Service Representatives may void the Warranty 2 4 Alternatively to clause 2 3 above Rinnai can at its discretion elect to pay you an amount equivalent to the cost of repairing or replacing the Product 2 5 If Rinnai provides you with either the replacemen...

Страница 31: ...ut not limited to faulty or poor external electrical wiring incorrect or faulty power supply voltage fluctuations over voltage transients or electromagnetic interference inadequate or faulty gas drainage services or water services including water pressure and non potable water d damage problems or failure caused by acts of God fire wind lightning flood storm hail storm fallout vandalism earthquake...

Страница 32: ... pays for the relevant freight charges in transit insurance expenses or travelling costs without written authorisation from Rinnai Rinnai will not reimburse the Purchaser for such costs 6 3 The Purchaser must pay all costs and expenses in respect of a any service call out fee if the Product is not accessible for service b making the Product accessible for service for example restricted access or w...

Страница 33: ...Page 33 NOTES ...

Страница 34: ...Page 34 NOTES ...

Страница 35: ...Page 35 NOTES ...

Страница 36: ...or further information visit www rinnai com au or email enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance If your appliance requires service please call our National Help Line Rinnai recommends that this appliance be serviced every 2 years With our policy of continuous improvement w...

Отзывы: