Warnings and Important Information
R32
WARNING
This appliance uses R32 (difluoromethane) refrigerant, which is a flammable gas class 2.2
according to AS/NZS 1677 and must be handled by a refrigeration mechanic with appropriate
Australian refrigerant handling licence.
WARNING
Risk of fire / flammable material. If the refrigerant is leaked, together with an
external ignition source, there is a possibility of ignition.
Read the OPERATING INSTRUCTIONS carefully before operation.
Service personnel are required to carefully read the OPERATING INSTRUCTIONS and
INSTALLATION MANUAL before operation.
Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION
MANUAL, and the like.
The appliance must be installed, used and stored in a ventilated area that is greater than 2m
2
.
The appliance must be placed in an area without any continuous sources of ignition (for example:
open flames, gas or electrical appliances in operation).
y
This appliance contains 480g of R32 refrigerant gas.
y
When cleaning the appliance, do not use any tools other than those recommended by the
manufacturing company.
y
Do not puncture and do not burn.
y
Refrigerant gases can be odourless.
y
If the appliance is installed, operated or stored in a non-ventilated area, the room must be
designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of
the refrigerant caused by electric heaters, stoves, or other sources of ignition.
y
The appliance must be stored in such a way as to prevent mechanical failure.
y
Repairs must be performed based on the recommendations from the manufacturing company. Maintenance
and repairs that require the assistance of other qualified personnel must be performed under the supervision of
an individual specified in the use of flammable refrigerants.
Mandatory Inspection Prior to Installation
Immediately report any damage or discrepancies to the Supplier of the appliance. This appliance was inspected
and tested at the time of manufacture and packaging, and released for transportation without known damage. Upon
receipt, inspect the exterior for evidence of rough handling in shipment. Ensure that the appliance is labelled correctly
for the gas and electrical supply, and/or other services it is intended to be connected to.
For safety and warranty purposes, appliances that may be damaged or incorrect
MUST NOT
be installed or operated
under any circumstances. Installation of damaged or incorrect appliances may contravene local government
regulations. Rinnai disclaims any liability or responsibility whatsoever in relation to the installation or operation of
damaged or incorrect appliances.
NOTE
A NOTE ON ILLUSTRATIONS
The illustrations used in this manual are for explanatory purposes only and the shape of your indoor unit
may vary slightly from that which is shown in this manual.
Содержание POLO PC47C
Страница 12: ...12 Name of Each Part and Function ...
Страница 13: ...13 Installation Installation Accessories Selection of Installation Location ...
Страница 14: ...14 Assembly ...
Страница 15: ...15 ...
Страница 16: ...16 ...
Страница 20: ...20 ...
Страница 23: ...23 Maintenance and Service Maintenance Methods Cleaning the Air Filter ...
Страница 24: ...24 End of Season Operations ...
Страница 25: ...25 Trouble Shooting ...
Страница 31: ...31 NOTES ...