Location

NOTE

• 

DO NOT

 install water controllers near a heat source, such as a cook top, stove or oven. Heat, 

steam, smoke and hot oil may cause damage. 

• 

DO NOT

 install water controllers outdoors unless protection from water / dust ingress and 

sunlight are provided.

•  The water controller set as the 

MASTER

 water controller 

MUST NOT

 be installed in a 

bathroom.

• 

DO NOT 

install water controllers in direct sunlight.

• 

DO NOT

 install water controllers against a metal wall unless the wall is earthed in accordance 

with local electrical authority rules.

•  Water controllers 

MUST NOT

 be installed where chemicals such as benzene, alcohol, 

turpentine, hydrogen sulphide, ammonia, chlorine or other similar chemicals are in use.

The Water controller is a water resistant device, however excessive exposure to water may result 

in damage to the controller. Durability is improved when positioned outside the shower recess.
• 

AVOID

 direct exposure to water or steam as these conditions may cause a malfunction.

• 

Water controllers must be installed in shaded and clean locations. They should be fitted out 

of reach of children (suggested height from floor to be at least 1500 mm). Water controllers 

MUST BE

 installed at least 400 mm above the highest part of a sink, basin or bath.

•  When cleaning your water controller use 

ONLY

 a damp cloth and a mild detergent.

Communication Cables

Water controllers operate at an extra low voltage (12 Volts DC) which is supplied from the water heater, a 10 metre 

long communications cable is supplied for connection to the water heater.

ONLY

 Rinnai supplied communication cables may be used. Optional longer communication cabling is available 

from Rinnai.

The water heater end of the cables are fitted with spade terminals. Only two pairs of cables (4 spade connectors in 

total) may be terminated. When attaching three or four cables it is necessary to join the cable terminals as follows:
For each pair cut off the existing spade connectors and re-terminate each pair into a new spade connector 

A

 

(spade connectors are available from your local electrical component retailer) so that there are only two sets of 

spade connectors (4 spade connectors in total) to be terminated.

Single cables can be used 

when terminating up to two 

communication cables.

Paired cables are to be used 

when terminating three or 

four communication cables.

A

Water Controllers Limitations

An installation can have up to 4 universal MC-601Q water controllers.

Deluxe kitchen, bathroom and wireless water controllers are also available and various combinations of universal 

and the deluxe and wireless controllers can be used with the following limitations:

• 

A maximum of 4 water controllers can be fitted. Any combination of deluxe and universal water controllers 

can be used with the following limitations:

• 

Only 

ONE

 master controller can be installed. This can be a deluxe kitchen, wireless or universal water 

controller (when programmed as a master controller).

NOTE

When a deluxe kitchen water controller is fitted it will always functions as a master controller, 

this is the default setting and can not be changed.

• 

Up to 

TWO

 deluxe bathroom water controllers can be installed.

• 

The 

FOURTH

 water controller in any installation 

MUST BE

 a wireless or universal.

For more information regarding deluxe kitchen, bathroom and wireless water controllers, contact Rinnai.

INSTALLATION

Содержание MC-601Q

Страница 1: ...ll deliver the selected temperature even when the water flow is varied or more than one tap is in use Only one MC model water controller can be designated as a Master water controller and this is normally used in the kitchen All the remaining water controllers are designated as Sub water controllers and are for use in bathrooms toilets and laundries The maximum temperature limit for all Sub water ...

Страница 2: ...ous Flow Water Heaters Operation Installation Manual Transferring Priority To control the water delivery temperatures when using two or more water controllers it is necessary to have priority transferred to the water controller you wish to use Transferring of priority will NOT be possible if the In Use indicator is currently illuminated as this indicates hot water is flowing and that another water...

Страница 3: ...on cables may be used Optional longer communication cabling is available from Rinnai The water heater end of the cables are fitted with spade terminals Only two pairs of cables 4 spade connectors in total may be terminated When attaching three or four cables it is necessary to join the cable terminals as follows For each pair cut off the existing spade connectors and re terminate each pair into a ...

Страница 4: ...ximately 5 seconds STEP 2 Check that the display on ALL FOUR water controllers is lit and displaying a temperature when switched on If any ONE of the water controllers displays two dashes see Fig 2 repeat STEP 1 This completes the activation procedure for the fourth water controller you may ignore Question 2 QUESTION 2 Is the water heater marked to state it delivers water not exceeding 50 C IF YES...

Отзывы: