Rinnai INFINITY operation guide 02-20 |  

 

INFINITY controllers

Water controllers are an optional extra. They allow precise temperature control

no need to mix 

hot and cold water.

General controller information

When used correctly the Rinnai INFINITY, when 

combined with digital controllers will deliver the 

selected temperature at the controller, even 

when the water flow varies, or when more than 

one tap is in use.

Each digital water controller can be individually 

programmed, though the INFINITY can 

only deliver one set temperature at a time. 

For example, someone is showering at a 

temperature of 43 

°

C, and another person uses 

the kitchen tap. The kitchen tap can only deliver 

43 

°

C until the person in the shower is finished. 

Available Rinnai controllers

• 

Compact, temperature selection only

 

• 

Kitchen Deluxe, temperature selection and 

voice prompting

 

• 

Bathroom Deluxe, temperature selection, 

shower saver, bath fill, and voice prompting

Controller configurations

A maximum of 

four 

(three for the N-Series) 

water controllers can be fitted, with the 

following provisos:

 

• 

Only one Kitchen Deluxe controller can be 

fitted. A Kitchen Deluxe is only installed if a 

Bathroom Deluxe controller is installed.

 

• 

Only two Bathroom deluxe controllers can 

be fitted.

 

• 

Only one controller can be set to deliver 

 

55 

°

C, this cannot be the controller in the 

bathroom.

Controllers need to be turned on

The Rinnai INFINITY will not heat the water 

unless the controller(s) are turned on. If water 

is flowing before a controller is turned on, the 

Rinnai INFINITY will not heat the water. Turn off 

the tap for a few seconds then turn on again.

Ignition problems

If the Rinnai INFINITY fails to ignite the ‘In 

Use’ indicator will not illuminate. The Rinnai 

INFINITY will not attempt re-ignition until the 

water flow is stopped for a few seconds and 

then restarted.

When gas bottles have been changed or the 

gas supply is disrupted (controller may display 

error code 11 or 12) ignition may fail and the ‘In 

Use’ indicator won’t be on. The water flow may 

need to be stopped and restarted several times 

before the appliance will operate.

Available temperatures on controllers (

°

C)

Kitchen (domestic)

37, 38, 39, 40, 41, 42, 43, 

44, 46, 48, 50, 55

Kitchen (commercial)

60, 65, 75

Bathroom (hot water)

37, 38, 39, 40, 41, 42, 43, 

44, 45, 46, 48, 50

Bathroom (bathfill)

37, 38, 39, 40, 41, 42, 43, 

44, 45, 46, 47, 48

For water temperatures lower than 37 

°

C, add 

cold water.

Содержание INFINITY A Series

Страница 1: ...INFINITY continuous flow water heaters Operation guide...

Страница 2: ...ries models are not suitable for solar installations Appliance must be installed commissioned and serviced by an authorised person being in New Zealand a licensed gasfitter Warning Improper installati...

Страница 3: ...applications should be serviced every two years Warning about hot water 4 Safety and important messages 4 About your water heater 5 General information 6 INFINITY controllers 7 Troubleshooting without...

Страница 4: ...safe level Safety and important messages This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge...

Страница 5: ...Instructions for draining the water heater can be found on p 10 How the water heater operates The burner lights automatically when the hot water tap is opened and goes out when the tap is closed Igni...

Страница 6: ...ife please consider what parts could be recycled for example scrap metal PCB etc Servicing Rinnai has a maintenance service and spare parts network with personnel who are fully trained and equipped to...

Страница 7: ...oller can be fitted A Kitchen Deluxe is only installed if a Bathroom Deluxe controller is installed Only two Bathroom deluxe controllers can be fitted Only one controller can be set to deliver 55 C th...

Страница 8: ...rruption during bathfill water will not flow when the power is back on Turn off all hot water taps and press On Off twice 05 Bypass flow control failure Service call 10 Air intake or flue blocked Serv...

Страница 9: ...call 51 Inlet thermistor failure Service call 52 Gas modulating valve faulty Service call 54 High exhaust gas temperature failure Service call 55 Scheduled service reminder1 Service call 61 Combustio...

Страница 10: ...water cools before draining as hot water will drain from the unit if there has been recent hot water use 1 Turn off any water controllers in the building and then turn off the water gas and power to...

Страница 11: ...e 02 20 11 Please note The hot water drain plug and water filter positions will vary depending on the model The images below are to highlight what they look like Hot water drain plug Water filter Hot...

Страница 12: ...r details refer to the pro rata table on p 14 2 Whichever comes first Residential application A residential application is defined as an installation where a continuous flow unit is set to 55 C3 or lo...

Страница 13: ...n reasonable access to the appliance will be chargeable by the attending service person for example removal of cupboards doors walls or the use of special equipment to move components but not limited...

Страница 14: ...es not include labour Water quality Water quality outside the limits as set down below will void this warranty Water quality and impurity limits TDS Total Dissolved Solids Total hardness CaCO3 Alkalin...

Страница 15: ...tailer address Date of purchase Product details Record your purchase details below Installer details Company name Installer name Address Phone Mobile Certificate of compliance number for installation...

Страница 16: ...barcode placeholder U340 1335X01 00 Tel 0800 746 624 http www youtube com rinnainz http facebook com rinnainz Rinnai co nz Operation guide...

Отзывы: