![Rinnai INFINITY 16 REU-V1616W Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/rinnai/infinity-16-reu-v1616w/infinity-16-reu-v1616w_service-manual_1462640032.webp)
Infinity REU-V1616W / REU-V1620W / REU-V2018W / REU-V2020W
- 2
7
-
Issue 2 - 21/03/06 ©Rinnai
4. Solenoid Valve 1 (SV
2
) Circuit
Check Solenoid 1 if error indicator “11” is displayed.
a.)
Disconnect Solenoid 1 connector (E
2
) and measure resistance between Blue and Black.
Normal:
1.7 ~2.0k
Ω
If normal, proceed to
b
.
Faulty:
Replace Solenoid 1.
b.)
Measure voltage between Blue and Black of Solenoid 1 connector.
Normal:
DC80~100V
If normal, proceed to Solenoid Valve 2 (SV
3
) Circuit
Faulty:
Replace PCB.
5. Solenoid Valve 2 (SV
2
) Circuit
a.)
Disconnect Solenoid Valve 2 connector (E
3
) and measure resistance between Yellow and Black.
Normal:
1.7 ~2.1k
Ω
If normal,, proceed to
b
.).
Faulty:
Replace Solenoid Valve 2.
b.)
Measure voltage between Yellow and Black of Solenoid Valve connector.
Normal:
DC80~100V
If normal, proceed to Thermal fuse Circuit.
Faulty:
Replace PCB.
6. Modulating Valve Circuit
a.)
Disconnect Modulating Valve fasten terminals and measure resistance between terminals.
Normal:
65~85
Ω
If normal, proceed to
b
.).
Faulty:
Replace Modulating Valve.
b.)
Measure voltage between Pink and Pink of Modulating Valve fasten terminal.
Normal:
DC2.0~15V
If normal, proceed to c.).
Faulty:
Replace PCB.
c.)
Check the gas secondary pressure change when set temperature on the remote control changes
from 37°C to 55°C.
Normal:
If secondary pressure changes, go to Water Flow Servo Circuit.
Faulty:
Replace Modulating Valve.
Содержание INFINITY 16 REU-V1616W
Страница 14: ...Convector 318H 9 Rinnai REU V2018W REU V20202W...
Страница 18: ...Infinity REU V1616W REU V1620W REU V2018W REU V2020W 13 Issue 2 21 03 06 Rinnai 7 Operational Flow Chart...
Страница 26: ...Infinity REU V1616W REU V1620W REU V2018W REU V2020W 21 Issue 2 21 03 06 Rinnai 12 Wiring Diagram...
Страница 27: ...Infinity REU V1616W REU V1620W REU V2018W REU V2020W 22 Issue 2 21 03 06 Rinnai 13 Dip Switch Settings...
Страница 47: ...Infinity REU V1616W REU V1620W REU V2018W REU V2020W 42 Issue 2 21 03 06 Rinnai 21 Exploded Diagram...
Страница 48: ...Infinity REU V1616W REU V1620W REU V2018W REU V2020W 43 Issue 2 21 03 06 Rinnai...
Страница 49: ...Infinity REU V1616W REU V1620W REU V2018W REU V2020W 44 Issue 2 21 03 06 Rinnai...
Страница 50: ...Infinity REU V1616W REU V1620W REU V2018W REU V2020W 45 Issue 2 21 03 06 Rinnai...
Страница 64: ...Infinity REU V1616W REU V1620W REU V2018W REU V2020W 59 Issue 2 21 03 06 Rinnai Notes...