FLUE REQUIREMENTS - INSTALLING
The following flue manufacturers with their specific brands listed below are approved for use
with the Rinnai Infinity 16i water heater.
1. UBBINK
The following combinations of flue materials may be used with the Rinnai water heater
Rolux® flue system
Roof terminal black T200 L =1000 mm
Wall terminal T200 Alu 800mm black
Wall terminal T200 Alu 800mm white
2. Muelink & Grol
The following combinations of flue materials may be used with the Rinnai water heater
Walloutlet 60/100 type M 2000 with short bend adaptor.
Roofoutlet 60/100 type M 2000 incl. adaptor.
Roofoutlet concentric 80/125 type M 2000
Concentric air/flue system 60/100 and 80/125.
Vertical appliance adaptor 60/100
3. Groppalli
The following combinations of flue materials may be used with the Rinnai water heater
A03.001.000813: Coaxial 60/100 wall flue kit;
A03.001.000276: Coaxial 60/100 90° bend;
A03.001.000278: Coaxial 60/100 1.000mm L pipe.
B0N.006.000001 Adaptor Kit from 60/100 to 80/125
A05.023.000021 Roof 80/125 flue
A05.025.000002 Roof tile