Servicing  

ANNUAL SERVICE 

See Page 25 

 
 

Isolate gas supply and electric supply 

 

Remove Front Panel by means of 4 corner screws 

 

Remove all screws around outer edge of manifold (11) and remove 

 

Inspect and clean injectors on inside of manifold (B). If  heavily contami-
nated remove front cover plate (A) and clean from inside out 

 

        

DO NOT RE-DRILL or ENLARGE ORIFICE 

 

Remove Ignition lead and Ionisation lead 

 

UNLESS GASKET (F)* IS AVAILABLE DO NOT REMOVE SCREWS (E) 

 

Remove remaining screws holding Combustion Chamber  Front Cover (10) 
and Remove Cover Plate 

 

Inspect and clean Ignition (C) and Ionisation Electrodes (D), Inspect for 
cracks. 

 

Remove 2 screws (12) on ledge of main burner box and remove complete 
burner 

 

Clean burners (G) with air brush and  paint brush 

 

Should any burner require individual attention undo screws (H) and remove 
retaining bracket (I) 

 

Inspect Combustion Chamber and base of Heat Exchanger. Check for signs 
of damage / leaking 

 

Disconnect fan wiring (J) 

 

Remove  3 x Fan retaining screws (13) and remove fan from unit 

 

Inspect fan Impellor and clean as require 

 

Re Build in Reverse Order 

Содержание Infinity 11e

Страница 1: ...Service Manual Continuous Flow Water Heater Important Read these instructions carefully before attempting installation or use of this appliance All work must be carried out by competent persons...

Страница 2: ...2 c...

Страница 3: ...3 June 2010 Issue 1 This manual is intended for use by Gas Safe Regisetred Engineers...

Страница 4: ...nd Pressures 9 4 Dimensions 10 5 Remote Controls 11 6 Cutaway Diagram 14 7 Operational Flow Chart 16 8 Main Components 17 9 Wiring Diagram 19 10 Dip Switch Setting 20 11 Error Codes 21 12 Diagnostic P...

Страница 5: ...5 Glossary of Terms and Symbols...

Страница 6: ...6 Introduction...

Страница 7: ...7 Specification...

Страница 8: ...8 Specification...

Страница 9: ...9 Water Flow Rates and Pressures...

Страница 10: ...10 Dimensions...

Страница 11: ...11 Remote Controls...

Страница 12: ...e over the system Select the desired temperature using the Hot water temp buttons The selected temperature will be displayed on all controller displays This is the water temperature which will be supp...

Страница 13: ...use there may be a variation between the temperature displayed at the controller and the temperature at the tap Do not clean the control with solvents or detergents Use only a soft damp cloth TEMPERAT...

Страница 14: ...14 Cutaway Diagram...

Страница 15: ...15 Cutaway Diagram...

Страница 16: ...16 Operational Flow Chart...

Страница 17: ...17 Main Components...

Страница 18: ...18 Main Components...

Страница 19: ...19 Wiring Diagrams...

Страница 20: ...20 Dip Switch Settings...

Страница 21: ...21 Error Codes...

Страница 22: ...22 Diagnostic Points...

Страница 23: ...23 Gas Pressure Setting...

Страница 24: ...24 Gas Pressure Settings...

Страница 25: ...25 Servicing Burner...

Страница 26: ...MOVE SCREWS E Remove remaining screws holding Combustion Chamber Front Cover 10 and Remove Cover Plate Inspect and clean Ignition C and Ionisation Electrodes D Inspect for cracks Remove 2 screws 12 on...

Страница 27: ...ible Check burner pressure as per page 23 Once burner pressures have been checked and correct turn off water outlets Isolate Gas supply and remove manometer Reseal Test Nipple Reinstate gas supply Ope...

Страница 28: ...28 Spares...

Страница 29: ...29 Spares...

Страница 30: ...30 Spares...

Страница 31: ...31 Spares...

Страница 32: ...32 Spares...

Страница 33: ...33 Spares...

Страница 34: ...34 Spares...

Страница 35: ...35 U K Warranty...

Страница 36: ...36 U K Contact Ver 1 19 10 21 RUK Tech Dept Ian Jenkins...

Отзывы: