Inbuilt Royale - ETR
- 15 -
Issue 4- ©Rinnai
The manufacturer reserves the right to change or modify specifications without notice.
Model:
Inbuilt Royale - ETR Flame Fire IB35ETR
Description:
Rinnai ETR Inbuilt Radiant/Convector, glass fronted, ceramic log
space heater with forced convection and natural draught flue system
Gas input rate:
Natural Gas
Propane
Pilot and ‘Low’:
8 MJ/hr
8 MJ/hr
Medium:
25 MJ/hr
25 MJ/hr
High:
33 MJ/hr
33 MJ/hr
Gas Control:
Rinnai electronic control
Burners
Ember bed and flame burner
Test Point Pressure:
0.95 kPa
2.00 kPa
Gas Connection:
1/2” compression flare
Flue terminal:
The flue must terminate to atmosphere vertically above the roof in
line to comply to AS/NZS 5601.
Rinnai Appliance warranty conditions will be voided if non Rinnai
Flue components are fitted. Rinnai are NOT CERTIFIED for use
with non Rinnai Flueing components.
Fan:
Tangential 2 speed, power rating 47 Watts
Combustion system
Multi port burner
Logs:
Ceramic
Ignition system:
Continuous spark electronic ignition
Operation:
Push button to light pilot and burners
Safety Devices:
Touch pad control.
Thermostatically controlled to light pilot and burners.
Able to select the following features:
- Timer
- Auto Off function
- Flame function
- Child lock
Combustion method:
Naturally aspirated burner
Installation type:
Inbuilt only
Weight:
54 Kgs.
Flue requirement:
A Rinnai approved flue system is mandatory for this appliance, to
be installed in accordance with AS/NZS 5601.
TECHNICAL SPECIFICATION