Flame Fire

Operating and Installation Instructions

Inbuilt Royale (Australia)

Timberflame IB35R (New Zealand)

Table of Contents

Customer Instructions

Operation
Safety Points
Troubleshooting

Installation Instructions

Location
Flueing
Gas Connection
Log Installation
Testing & Commissioning
Technical Data
Service Contacts
Installation Checklist
Installer Details

IMPORTANT

This appliance shall be installed in accordance with:

Manufacturers Installation Instructions.

    Local Gas fitting regulations.

    Municipal Building codes.

    AGA Gas Installation Code AG601 - NZ 5261.

    Any other relevant statutory regulation.

    Rinnai strongly recommend that this product be installed with an

     approved flue system for optimum product performance.

    This appliance must only be installed, serviced and removed by an

      authorised person.

 

   

For Australian installation, this appliance must be installed with

      the supplied wire dressguard.

This heater is NOT designed to be built directly into any combustible
opening

.

For combustible opening installations, a Rinnai Zero Clearance Kit is
available from your Gas Appliance Retailer.

2
3

4

5
6
8

9

10

11

11
12
12

Содержание IB35R

Страница 1: ...ions Local Gas fitting regulations Municipal Building codes AGA Gas Installation Code AG601 NZ 5261 Any other relevant statutory regulation Rinnai strongly recommend that this product be installed wit...

Страница 2: ...erials be present on the inside of the fireplace recess or flueway Note A Rinnai Zero Clearance kit is available where the heater is required to be installed in close proximity to combustible framing...

Страница 3: ...scharge into the room The chimney must be free of soot and creosote accumulation resulting from previous slow combustion wood fires It must also be clear of all blockages and swept prior to installati...

Страница 4: ...les F Soot Creosote accumulation G Structural deterioration H Loose or broken bricks I Smoke Pellet test Leakage FLUEING SEALING THE INBUILT INSTALLATION Peel protective backing off the foam strips su...

Страница 5: ...heater is installed If the fire has to be removed the plate will pivot backwards to allow the heater to slide clear When a flue liner or Zero Clearance Box is used the flue protector plate must be un...

Страница 6: ...pins of the Main Log as shown Gently place loose ember bed material in front of the front log Do not pour as dust particles from the plastic bag may block the burner ports Level it with a pencil or s...

Страница 7: ...els All burner aeration is factory preset and cannot be adjusted If you are unable to get the unit to operate correctly refer to Troubleshooting on Page 4 before contacting your local service agent as...

Страница 8: ...Z Tangential 2 Speed Watt Rating 90W Inside right hand side panel 11 SERVICE CONTACT POINTS RINNAI AUSTRALIA PTY LTD ACN 005 138 769 Helpline 1300 366 388 Mon Fri 8 30am 5 30pm EST Cost of a local cal...

Страница 9: ...place 8 Has the appliance been commissioned 9 Is the end user fully aware of operating procedure NO YES INSTALLER GASFITTER DETAILS Company Name _______________________________________________________...