YOur
LOCATION
When positioning the heater, the main points governing the location are:
1. Flueing.
2. Warm air distribution.
3. The heater must not be installed where curtains or other combustible materials could come
into contact with it. In some cases, curtains may need restraining.
See below for minimum clearances required.
4. The heater is not designed to be built into bookcases or shelves or any combustible
opening.
5. Under no circumstances must combustible materials be present on the inside of the
fireplace recess or flueway.
Note:
A Rinnai Zero Clearance kit is available where the heater is required to be installed
in close proximity to combustible framing.
6. The heater must be mounted on a hearth no less than 50mm. high and the width and
depth of heater.
7. Check that room ventilation complies with local regulations.
8. Check that an EARTHED power point is within 1500mm. of the right hand side of the
heater.
5
Your new Flame Fire is designed to be installed in a masonry fire place.
The appliance can also be built into a non-masonry application by installing a
Rinnai Zero Clearance box and an approved flue system.