Rinnai HOTFLO EHFA 250 Скачать руководство пользователя страница 7

Rinnai 

EHFA/EHFD HW IM

SAFETY DEVICES

For safe operation this water heater is fitted with a combination Pressure & Temperature Relief Valve, a thermostat 

and an over-temperature cut out for each heating element�

WARNING

DO NOT 

tamper with or remove safety devices.

DO NOT

operatethiswaterheaterunlessallsafetydevicesarefittedandinworkingorder.

Theoperationofthethermalcutoutindicatesapossiblydangeroussituation.

DO NOT 

reset the 

thermalcutoutuntilthewaterheaterhasbeenservicedbyaqualifiedperson.

Pressure & Temperature Relief (PTR) Valve

This valve is located near the top of the water heater and is essential for safe operation�

WARNING

DO NOT 

sealorblocktheoutletofthePTRvalveoritsdrainpipe.

DO NOT 

replacethePTRvalvewithonethathasahigherpressureratingthanisspecifiedfor

the water heater.

The PTR valve should be checked for performance or replaced at intervals not exceeding 5 years, or more frequently 

in areas with a high incidence of water deposits by a qualified person. The easing gear must be operated at least 

once every six months or more frequently in areas with a high incidence of water deposits�

WARNING

Failure to do this may result in the water heater cylinder failing or under certain circumstances, 

exploding.Waterdischargedwillbeveryhot.Exercisecaretoavoidscaldinjury.Ifthevalvedoes

notsealagainwhentheeasinggearisclosed,contactRinnaitoarrangeinspectionbyaqualified

person.

It is important you raise and lower the easing gear gently� If the valve does not 

discharge water when the easing gear lever is lifted, there may be a serious 

problem and the power supply in the meter box (the switch marked ‘Water 

heater’ or ‘hot water’) or the isolating switch installed near the water heater 

must be switched off immediately� Contact Rinnai to arrange inspection by 

a qualified person.

It is normal for the PTR valve to release a small quantity of water through the drain pipe during heating� If the valve 

dribbles or leaks continuously, try easing the valve gear for a few seconds� This may dislodge any foreign matter 

and stop leakage� If leakage does not stop there may be a problem as detailed below: 

• 

If there are heavy flows of water until the water heater is cold which then stops until the water reheats there may 

be a serious problem and the power supply in the meter box (the switch marked ‘Water heater’ or ‘hot water’) or 

the isolating switch installed near the water heater must be switched off immediately� Contact Rinnai to arrange 

inspection by a qualified person. 

• 

If there is a steady flow for long periods, often at night, it may be as a result of the water pressure exceeding the 

design pressure of the water heater� Contact your installing plumber as a Pressure Limiting Valve (PLV) may 

be required�

Expansion Control Valve (ECV)

An ECV is recommended in all geographical areas where the water supply has a tendency to cause scaling, 

including South Australia and Western Australia. Local regulatory authorities may require that an ECV be fitted. 

The ECV is to be supplied and fitted by the installer. Refer to the section Water Quality for more information on 

scaling water�

If an ECV is fitted, operate the easing gear at least once every six months to remove any deposits and to verify 

that it is not blocked�
The ECV should be checked for performance or replaced at intervals not exceeding 5 years, or more frequently in 

areas with a high incidence of water deposits by a qualified person.  

It is normal and desirable that the ECV allows a small quantity of water to be discharged through the drain pipe 

during the heating cycle� If the valve dribbles or leaks continuously, operate the easing gear for a few seconds� This 

may dislodge any foreign matter and stop leakage� If leakage does not stop Contact Rinnai to arrange inspection 

by a qualified person.

Gently lift lever 

until water flows 

from drain line, 

lower lever gently 

to close

WARNINGS & SAFETY

Содержание HOTFLO EHFA 250

Страница 1: ...ZS 3500 4 Plumbing and Drainage Heated Water Services All local regulatory requirements including all local OH S requirements This appliance must be installed maintained and removed by a Qualified Per...

Страница 2: ...Rinnai 2 EHFA EHFD HW IM...

Страница 3: ...cifications 11 Installation Methods 12 Hot Water Plumbing System Example No TLD 12 Hot Water Plumbing System Example With TLD 12 Hot Water Plumbing system Example Flow Return Pipe Work No TLD 13 Hot W...

Страница 4: ...Rinnai 4 EHFA EHFD HW IM This page is intentionally blank...

Страница 5: ...ons For continued safety of this appliance it must be installed operated and maintained in accordance with the manufacturer s instructions This appliance is heavy use 2 people or mechanical lifting de...

Страница 6: ...ING The thermostat setting must only be adjusted by an Electrician or other suitably qualified trades person The access cover to the element and thermostat must only be removed by an Electrician or ot...

Страница 7: ...son It is normal for the PTR valve to release a small quantity of water through the drain pipe during heating If the valve dribbles or leaks continuously try easing the valve gear for a few seconds Th...

Страница 8: ...et period and stored The Off Peak supply is usually cheaper Electricity supply types and tariffs vary according to the local electricity authority Twin Element Model A vitreous enamel lined steel cyli...

Страница 9: ...innai to discuss adjusting the thermostat No water from the hot tap Restriction in the hot tap or failure of the cold water supply to the heater Check for water flow at the other hot taps and that the...

Страница 10: ...mm use supplied PTR Valve 8 Anode cap 9 Right hand duplicate hot water outlet Connection RP 3 4 20mm use a union connection and insulate hot water pipe 10 Right hand duplicate cold water inlet 11 Wate...

Страница 11: ...s 680 680 680 Recommended PLV pressure rating 500 500 500 ECV Not Fitted kPa Fit PLV if mains pressure exceeds 800 800 800 Recommended PLV pressure rating 500 500 500 Rated Capacity Hot Water Litres l...

Страница 12: ...Isolating Valve Isolating Valve PLV ECV OR WATER HEATER Non return Valve COLD SUPPLY Non return Valve Non return Valve WATER HEATER Temperature Limiting Device TLD Non return Valve PTR VALVE Supplied...

Страница 13: ...RETURN PIPE WORK WITH TLD COLD SUPPLY Isolating Valve ECV TO DRAIN Non return Valve PLV KITCHEN LAUNDRY NON TEMPERED SUPPLY BATHROOM ENSUITE TO DRAIN PTR VALVE Supplied WATER HEATER Not Supplied Non...

Страница 14: ...cur as a result of water leakage the water heater MUST BE installed with a safe tray overflow tray and drain Construction installation and draining of the safe tray MUST comply with local regulatory r...

Страница 15: ...ations WARNING Valves with pressure ratings other than specified MUST NOT be used An isolation valve and non return valve MUST BE fitted in the cold water supply to the water heater so the water heate...

Страница 16: ...alve outlet in accordance with the section Relief Valve Drain Lines on the bottom of page 16 The valve body MUST BE insulated in accordance with local regulatory requirements and AS NZS 3500 4 to opti...

Страница 17: ...e local electricity supplier The Off Peak overnight is usually the most economical for the customer Electrical Connections WARNING The water heater MUST BE filled with water prior to connection to the...

Страница 18: ...e access cover to the element and thermostat The access cover to the element and thermostat MUST ONLY BE removed by an Electrician or other suitably qualified trades person The thermostat setting MUST...

Страница 19: ...orced out of the taps 3 Close each tap when water runs freely without air bubbles 4 Check all plumbing connections and pipe work for water leaks 5 Connect the water heater to the electricity supply an...

Страница 20: ...our National Help Line Rinnai recommends that this appliance be serviced every year Head Office 100 Atlantic Drive Keysborough VIC 3173 P O Box 460 Braeside Victoria 3195 Product Sales and Service Na...

Отзывы: