Rinnai 13 HW_CF_FFPP_FIM

FLUE COMPONENT DIMENSIONS

DESCRIPTION

CODE NUMBER

BAR CODE NUMBER

90 Degree Bend

FFPPBEND90

9314109415049

45 Degree Bend

FFPPBEND45

9314109415056

Horizontal Flue Terminal

FFPPWALLKIT

9314109415032

Flue Pipe 1000mm length

FFPPPIPE1000

9314109415018

Vertical Flue Terminal

FFPPROOFCOWL

9314109415025

Ceiling Ring

FFWSEAL

9314109107722

FFPPBEND45

Includes:

45° Bend (x2)

FFWSEAL

Includes:

Ceiling Ring

225

125

Thickness 1mm

FFPPROOFCOWL

Includes:

Vertical Terminal Pipe

UV Adaptor (x1)

UV Protector (x2)

Pipe Clip/Wall Bracket (x1) 

Installation Instruction

FFPPBEND90

Includes:

90° Bend

FFPPWALLKIT

Includes:

Starter Bend (FFPPBEND90)

Horizontal Terminal Pipe

Internal Wall Seal (White)

External Wall Seal (Black)

Installation Instruction

FFPPPIPE1000

Includes:

Flue Pipe

Pipe Clip/Wall Bracket (x1)

Minimum Offset

70

10

125

80

980

UP

5

85

451

10

125

80

967

30

150

30

10

125

80

225

Max. Wall Thickness 445

12

80

125

147

144

62.5

96

73

170

10

80

125

124

11

5

62.5

73

125

70

10

80

125

124

11

5

62.5

73

125

834

657

153

(As a 45° OFFSET)

Minimum Offset

192

(As a 90° OFFSET)

230

SPECIFICATIONS

Содержание HD210i

Страница 1: ...uit Rinnai Water Heater Models HD210i REU N3237FFC AK The flue components described within these instructions are ONLY suitable for use with the model s that is listed above They are NOT suitable nor...

Страница 2: ...This appliance must be installed in accordance with Manufacturer s Installation Instructions Current AS NZS 3000 AS NZS 3500 AS NZS 5601 Plumbing Code of Australia PCA Local Regulations and Municipal...

Страница 3: ...ns 6 UV Roof Protectors 6 Installation methods 7 FFPP Flueing Options 7 Direct Horizontal Flue 8 Extended Horizontal Flue 8 Vertical Flue 9 Combined Vertical Horizontal Flue 10 Condensate Drain 10 Imp...

Страница 4: ...m to local regulations All dimensions referred to in these instructions are in millimetres unless otherwise specified These instructions ONLY apply to the Rinnai FFPP water heater coaxial flueing syst...

Страница 5: ...ght The ONLY COMPONENTS that can be cut are as follows FFPPWALLKIT pipe not bend FFPPPIPE1000 FFPPROOFCOWL and UVROOF PROTECTORS Ensure all ends are cut square the use of a mitre box will ensure a cle...

Страница 6: ...he relevant spacing and clearance dimensions for both vertical and horizontal multiple terminal installations Multiple Roof Terminal Installations The minimum horizontal separation between terminal ce...

Страница 7: ...same as Direct Horizontal flueing with additional pipe required due to the longer horizontal distance Refer Extended Horizontal Flue on page 8 for details of this installation method C Vertical Flue I...

Страница 8: ...as required Fit the internal wall seal to the terminal pipe 6 Connect the terminal pipe to starter bend ensuring components are pushed fully home Secure the PVC joints of bend to the terminal pipe wit...

Страница 9: ...cut to size as required see Fig 1 in section Cutting The Flue Components on page 5 5 Install decktite roof seal Not supplied 6 Ensure the flue is fully supported independently of the appliance by the...

Страница 10: ...pipes and fittings such as Unplasticised Polyvinyl Chloride UPVC or Polyethylene PE which is commonly used for irrigation piping Important Considerations For Condensate Drain Pipe NOTE The content of...

Страница 11: ...ers may be joined together provided they conform with the requirements of the Installation Method on page 11 Common Stack Discharge Where individual water heaters are installed in a multi storey build...

Страница 12: ...URE 6 2 in part LOCATION OF FLUE TERMINALS OF BALANCED FLUE ROOM SEALED FAN ASSISTED OR OUTDOOR APPLIANCES n j Horizontally from an openable window door non mechanical air inlet or any other opening i...

Страница 13: ...FPPROOFCOWL Includes Vertical Terminal Pipe UV Adaptor x1 UV Protector x2 Pipe Clip Wall Bracket x1 Installation Instruction FFPPBEND90 Includes 90 Bend FFPPWALLKIT Includes Starter Bend FFPPBEND90 Ho...

Страница 14: ...Rinnai 14 HW_CF_FFPP_FIM NOTES...

Страница 15: ...Rinnai 15 HW_CF_FFPP_FIM NOTES...

Страница 16: ...nformation visit www rinnai com au or email enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai...

Отзывы: