1. Convection fan starts, drawing air in through
the back of the cabinet and across the heat
exchanger / burner chamber and out into the
space. The PCB verifies fan rotation.
2. Once the fan is running at the proper speed,
spark ignition begins.
3. After spark begins, the gas valve solenoids
open allowing gas into the burner.
4. Ignition occurs and flame develops across the
burner.
5. The PCB will verify flame with thermocouples
and turn off the sparker.
6. Warm air then begins to flow into the space.
7. PCB will determine gas input and fan speed
settings based on the room temperature
measurement from the room thermistor.
8. When thermostat set point is reached the gas
valve solenoids close. The combustion fan will
continue to run to cool down the unit.
9. When the room temperature drops below the
set point, the process will start again.
Sequence of Operation
Spark
Electrode
P
C
B
Room
Temperature
Thermistor
POV
SV1
Thermocouple 2
Convection
Fan Assembly
Thermocouple 1
Gas Valve
Solenoids
Combustion
Chamber
Содержание FC510N
Страница 1: ...Rinnai Fan Convector Heaters Level III Training 1...
Страница 2: ...Fan Convector Heaters FC510 RCE 391A FC824 RCE 691TA...
Страница 3: ...Internal Components FC510 RCE 391A FC824 RCE 691TA...
Страница 14: ...Error Codes Troubleshooting 14...
Страница 17: ...Wiring Diagram...
Страница 26: ...Burner Assembly Removal Next Seven Slides...
Страница 34: ...Cleaning Burner Assembly...
Страница 36: ...Cleaning ODS Pilot Orifice...
Страница 38: ...Fan Motor Squirrel Cage Blower Removal Next Six Slides...
Страница 44: ...The End Fan Convection Heater Service Training 44...