HD250i Combination Flueing Installation: 0-08
HD250i Combination Flue Components
FFHD250INLET
HD250i Air Inlet
Air inlet required on all installations, mesh included.
FFHD250COWL
HD250i Vertical Roof Termination Cowl
Stainless steel roof cowl used to terminate vertical installations.
FFHD250BEND90
HD250i Flue 90° Bend
Stainless steel 90° bend used to facilitate between horizontal and vertical
flueing. Maximum of three 90° bends can be used.
55
55
FFHD250BEND45
HD250i Flue 45° Bend
Stainless steel 45° bend used to offset obstructions.
96.4
96.4
FFHD250PIPE300
HD250i Flue Pipe 300mm
Stainless steel 300mm stainless steel pipe, can not be cut to
size.
FFHD250PIPE900
HD250i Flue Pipe 900mm
Stainless steel 900mm stainless steel pipe, can not
be cut to size.
FFHD250PIPEADJ
HD250i Flue Adjustable Length
Stainless steel adjustable flue pipe recommended for use as
the first flueing component off the Infinity unit for both the
air intake and exhaust flue. Pipe can not be cut to length.
300
50
900
50
50
80~270
Connect the pre-greased components. Ensure the O-Rings are not
damaged during this process. Ensure the flue is locked in position.
Push the components tightly together and press the small locking tab.
While holding the small tab in, gently slide the components apart. Ensure
the O-Rings are not damaged during this process.
To Connect the
Flue Components
To Disconnect the
Flue Components