HD250i Combination Flueing Installation: 0-08

HD250i Horizontal, 

Vertical and Combination 

Flueing

Installation Manual

This appliance shall be installed in accordance with:

• Manufacturer’s Installation Instructions

• Local Gas Fitting Regulations

• NZS 526 Installation Code

• Municipal Building Codes

• Any other local relevant statutory regulation

Installation and service must be performed by an authorised person.

Содержание Efficiency HD250i

Страница 1: ...ing Installation Manual This appliance shall be installed in accordance with Manufacturer s Installation Instructions Local Gas Fitting Regulations NZS 5261 Installation Code Municipal Building Codes...

Страница 2: ...and fully check the operation of the water heater before leaving site including the temperature of the water delivered WARNING Improper installation adjustment alteration service or maintenance can c...

Страница 3: ...ue components from other manufacturers Only the flue components identified in this installation manual are to be used for horizontal vertical and combination flueing The exhaust flue components are si...

Страница 4: ...Exhaust Exhaust Intake Relationship Condensate Each requires a 90 bend to prevent entry of rain Intake must be located in relation to the exhaust as shown below Horizontal flues must slop 20mm per met...

Страница 5: ...ensate drain and trap as close as possible to the appliance Condensate drain trap must contain a minimum of 75mm 500mm clearance shown is for simple roof pitches Complex multiple pitched roofing can i...

Страница 6: ...ion Predrill two small holes at the end of the air intake pipe Slide the pipe over the air intake terminal 2 With self tapping screws attach the pipe to the air intake terminal 3 Apply a bead of silic...

Страница 7: ...tainless steel 300mm stainless steel pipe can not be cut to size FFHD250PIPE900 HD250i Flue Pipe 900mm Stainless steel 900mm stainless steel pipe can not be cut to size FFHD250PIPEADJ HD250i Flue Adju...

Страница 8: ...Installers 0800 TO RINNAI 0800 86 746 624 Rinnai New Zealand Limited 105 Pavilion Drive Airport Oaks PO Box 53177 Mangere Auckland Airport Manukau Manukau 2150 Phone 09 257 3800 Fax 09 257 3899 Email...

Отзывы: