background image

Rinnai 

 Ducted Reverse Cycle Inverter  OM

OPERATION
DO NOT

 let the air conditioner run for extended periods when the humidity is very high or when doors or 

windows are left open� As this may result in an excessive operational loading and lead to product failure�

DO NOT

 cover or place articles on any part of this appliance�

DO NOT

 touch, operate or clean the air conditioner with wet hands� It may result in electric shock or 

product failure�

DO NOT

 insert hands or other objects through the air inlet or outlet of the appliance it may result in 

electric shock or product failure�

DO NOT

  place  a  heater  or  other  heating  appliances  near  this  appliance,  always  ensure  sufficient 

ventilation when using this appliance and a heating appliance at the same time� Failure to do so may 

result in product miss-operation�

Turn main power off before cleaning. Failure to do so may result in fire, electric shock, or product failure.

DO NOT

 use solvents, abrasives or harsh detergent to clean any part or surface of this appliance or 

spray water or allow liquids to enter the indoor unit� The enclosure of the appliance and remote control 

can be cleaned using a soft, damp cloth and a mild detergent�

NEVER

 touch the metal parts of the air conditioner when you remove the air filter. It may result in electric 

shock or product failure�

DO NOT

 leave flammable materials near the appliance. It may result in explosion or fire.

If there is excessive noise, smell or smoke coming from the appliance, turn the appliance 

OFF,

 isolate 

the power supply and contact a service agent� 

DO NOT 

operate the appliance if it has been submerged into water due to flooding, contact a service 

agent. Failure to do so may result in electric shock, fire, serious injury, or product failure.

This appliance is 

NOT 

intended for use by persons (including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and knowledge unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for their safety�

Children should be supervised to ensure that they do not play with the appliance�

The air conditioning system is designed to achieve consumer comfort� It is not designed for commercial 

applications requiring a controlled atmosphere (i�e� computer rooms, food preservation, etc�)

DO NOT 

block the inlet or outlet of air flow. It may result product failure.

DO NOT

 drink the condensate water drained from the appliance� This condensate is not potable and may 

present a health risk if consumed�

DO NOT 

expose people, animals or plants directly to the cold or hot discharge of the appliance� It may 

result in serious injury�

DO NOT

 mix the batteries for the remote control with other types of batteries or mix new batteries with 

used batteries� Failure to do so may result in product failure� 

STOP

 using the remote control if there is a 

battery fluid leak.

DO NOT

 use an extension cord, manually extend the power cord, or connect other appliances to the 

same outlet as the air conditioner. Poor electrical connections, poor insulation, and insufficient voltage 

can cause fire.

NOTE

A NOTE ON ILLUSTRATIONS

The illustrations used in this manual are for explanatory purposes only and the shape of your indoor unit 

may vary slightly from that which is shown in this manual� 

WARNING

WARNINGS AND IMPORTANT INFORMATION

Содержание DINLR07Z72

Страница 1: ...nce must be installed maintained and removed only by an Authorised Person For continued safety of this appliance it must be installed and maintained in accordance with the manufacturer s instructions Owner s Manual Ducted Reverse Cycle Inverter Outdoor Units Indoor Units DONSR07Z72 DINLR07Z72 DONSR10Z72 DINLR10Z72 Z721 DONSR12Z72 DINLR12Z72 DONSR14Z72 DINLR14Z72 DONSR17Z72 DINLR17Z72 Rinnai Ducted...

Страница 2: ...Rinnai 2 Ducted Reverse Cycle Inverter OM This page is intentionally blank ...

Страница 3: ...aintenance Pre Season Inspection 7 Installation Record Installer Details 8 Installation Record System Details 8 Customer care Program 8 Service Maintenance Schedule Ducted Air Conditioning Systems 9 Save A Service Call 10 General User Guide 12 Operation and Maintenance 12 Operating your system 12 Cooling Cycle 13 Heating Cycle 13 Zoned Systems 13 Performing Routine Maintenance 13 Checking The Air ...

Страница 4: ...l surface or where there may be a danger of it falling It may result in death serious injury or product failure DO NOT install the outdoor unit where noise may cause nuisance DO NOT install the outdoor unit where it will be exposed to sea wind salt spray as this will reduce durability ACHIEVING OPTIMAL PERFORMANCE For optimal performance ensure to use the air conditioner within the following tempe...

Страница 5: ...rate the appliance if it has been submerged into water due to flooding contact a service agent Failure to do so may result in electric shock fire serious injury or product failure This appliance is NOT intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concern...

Страница 6: ...e you perform any maintenance otherwise it may cause electric shock When removing filter do not touch metal parts in the unit The sharp metal edges can cut you DO NOT use chemicals or chemically treated cloths to clean the filters DO NOT use benzene paint thinners polishing powder or other solvents They can cause the plastic surface to crack or deform NEVER use water that is hotter than 40 C when ...

Страница 7: ... Fan function until unit dries out completely Turn off the unit and disconnect the power Remove batteries from remote control MAINTENANCE PRE SEASON INSPECTION After long periods of non use or before periods of frequent use do the following Check for damaged wires Clean all filters Check for leaks Replace batteries Make sure nothing is blocking all air inlets and outlets of both the indoor or outd...

Страница 8: ...__________________ Serial Number Outdoor Unit ________________________________________________________________ Installation Address ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ CUSTOMER CARE PROGRAM Please ensure you register your product warranty on...

Страница 9: ...g Heating o C o C o C o C o C o C Outlet Air Temp Cooling Heating o C o C o C o C o C o C Outdoor unit Liquid line a P k a P k a P k a P k a P k a P k e r u s s e r p Outdoor unit Suction line a P k a P k a P k a P k a P k a P k e r u s s e r p Zone Operation If Applic Ductwork and fittings Return Air grille filters Airflow through system Refrigerant pipework Safety tray Zone motors CONSUMABLES Capac...

Страница 10: ...he indoor unit and is normal Both the indoor unit and outdoor unit make noises Low hissing sound during operation This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units Low hissing sound when the system starts has just stopped running or is defrosting This noise is normal and is caused by the refrigerant gas stopping or changing direction The outdoor unit mak...

Страница 11: ...to the cooling heating or auto The air inlet or outlet of either unit is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the unit Excessive heat is generated by sunlight Close windows and curtains during periods of high heat or bright sunshine Too many sources of heat in the room people ...

Страница 12: ... have unrestricted airflow Do not cover the unit lean any thing against it or stand upon it Do not allow grass clippings leaves or other debris to accumulate around or on top of the unit Maintain a minimum of 300mm clearance between the outdoor unit and tall grass shrubs vines etc Your Thermostat Controller is the control centre for your system Please familiarise yourself with its specific operati...

Страница 13: ... may condense into a mist in the cold outdoor air ZONED SYSTEMS Some home comfort systems are designed to operate on a zoned basis only i e they are not designed to heat and or cool the entire home or space at one time Generally a zoned system will be designed by your Installer for your specific requirements Your particular zoning configuration and the basis of design should be specified and detai...

Страница 14: ...he FCU should be maintained at a position that ensures condensate drainage from the unit In an attic space ideally the unit will be easily and safely accessible from the ceiling access panel have a suitable catwalk and platform and if necessary a service light The outdoor Condensing Unit CDU requires adequate support to ensure it is level CDUs generate condensate water in the heating mode dependin...

Страница 15: ... the law requires special collection and treatment DO NOT dispose of this product as household waste or unsorted municipal waste IMPORTANT Special notice Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad for the environment Hazardous substances may leak into the ground water and enter the food chain GENERAL USER GUIDE ...

Страница 16: ...ans 8 30am to 5 00pm Monday to Friday excluding public holidays 7 Operating Installation Instructions means the user manual or other documentation which provides detailed instructions on the proper operation and maintenance of the Product 8 Other Applications means any Product used for purposes other than Residential Light Commercial Applications OtherApplications may include but are not limited t...

Страница 17: ... performed during Normal Business Hours by anAuthorised Service Representative Repair by persons other than anAuthorised Service Representatives may void the Warranty 2 4 Alternatively to clause 2 3 above Rinnai can at its discretion elect to pay you an amount equivalent to the cost of repairing or replacing the Product 2 5 If Rinnai provides you with either the replacement costs or replacement pr...

Страница 18: ...or poor external electrical wiring incorrect or faulty power supply voltage fluctuations over voltage transients or electromagnetic interference inadequate or faulty gas drainage services or water services including water pressure and non potable water d damage problems or failure caused by acts of God fire wind lightning flood storm hail storm fallout vandalism earthquake war civil insurrection m...

Страница 19: ...t freight charges in transit insurance expenses or travelling costs without written authorisation from Rinnai Rinnai will not reimburse the Purchaser for such costs 6 3 The Purchaser must pay all costs and expenses in respect of a any service call out fee if the Product is not accessible for service b making the Product accessible for service for example restricted access or working at heights or ...

Страница 20: ...t this appliance be serviced at least every 2 years With our policy of continuous improvement we reserve the right to change or discontinue at any time specifications or designs without notice Australia Pty Ltd ABN 74 005 138 769 100 Atlantic Drive Keysborough Victoria 3173 P O Box 460 Braeside Victoria 3195 AU45204 Product Sales Service National Help Line Tel 1300 555 545 Fax 1300 555 655 Monday ...

Отзывы: