5.7 GENERAL ARRANGEMENT DRAWINGS & CLEARANCE REQUIREMENTS
Figure 14.
Outdoor Unit: DO-SC18Z91 & DO-SC22Z91 (dimensions in mm)
1258
450
508
PLAN VIEW
FRONT
PLAN VIEW
Recommended Clearance
SIDE
NOTE 6
NOTE 3
NOTE 5
NOTE 4
NOTE 2
450
1390
1219
1169
751
NOTE:
1. Unit illustrated is a horizontal single
stage outdoor unit
2. Recommended lifting point. Use soft
slings under unit in area indictated
3. Access panel
4. Refrigerant pipe
22 kW : (LIQØ 12.7, SUCT. Ø28.6)
18 kW : (LIQØ 12.7, SUCT. Ø22.2)
5. Electrical entries
6. Electrical switchboard
7. Unit weight:
DO-SC18Z91 - Net:141 kg, Gross 150 kg
DO-SC22Z91 - Net:144 kg, Gross 153 kg
900
150
900