![Rinnai CU160e Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/rinnai/cu160e/cu160e_installation-and-operation-manual_1463009085.webp)
Figure 84: Piping Diagram
HOT
COLD
ON!
Cold Drain
Valve
Cold Isolation
Valve
PRV Lever
Hot Isolation
Valve
Hot Drain
Valve
Condensate
Trap Drain Plug
Condensate
HOT
P
RV
COLD
Rinnai Tankless Water Heater Installation and Operation Manual
85
6.4 Draining the Water
Heater
To avoid burns, wait until the equipment
cools down before draining the water. The
water in the appliance will remain hot after it
is turned off.
WARNING
If the water heater is not going to be used
during a period of possible freezing weather, it
is recommended that the water inside the water
heater be drained.
To manually drain the water:
1.
Shut off cold water supply and gas supply.
2.
Turn off the temperature controller.
3.
Disconnect the power to the water heater.
4.
Close the hot and cold isolation valves.
5.
Open the pressure relief valve (PRV) lever.
6.
Open the hot and cold drain valves.
7.
Remove the condensate trap drain plug and
allow to drain.
8.
Remove the pump drain plug (only for pump
version).
To resume normal operation:
1.
Confirm that the gas supply is turned off, all
taps are closed and PRV lever is closed.
2. Insert the condensate trap drain plug.
3.
Close the hot and cold drain valves.
4.
Open the cold and hot water isolation valves.
5.
Open a tap and confirm that water flows, and
then close.
6.
Connect power to the water heater.
7.
After confirming that the temperature controller
is off, turn on the gas supply.
8.
Turn on the temperature controller.
Running a low volume of water through the
water heater to prevent freezing:
If the temperature exceeds the ability of the water
heater to freeze protect itself, or if power is lost,
the following steps may prevent the water heater
and external piping from freezing. Units connected
with EZConnect™ (2-unit link) should be drained
to prevent freezing if not in use.
1.
Turn the water heater off and
close the gas supply valve.
2.
Turn on a hot water tap to flow
water about 0.1 gal/min (0.4
L/min) or where the stream is
about 0.2 in. (5 mm) thick.
When the water heater or external piping has
frozen:
1.
Do not operate the water heater if it or the
external piping is frozen.
2.
Close the gas and water valves and turn off
the power.
3.
Wait until the water thaws. Check by opening
the water supply valve.
4.
Check the water heater and the piping for
leaks.
Figure 83
Содержание CU160e
Страница 88: ...Figure 86 Rinnai Tankless Water Heater Installation and Operation Manual 88 7 2 WiringDiagram PC BOARD...
Страница 89: ...Rinnai Tankless Water Heater Installation and Operation Manual 89 7 3 LadderDiagram Figure 87...
Страница 94: ...Rinnai Tankless Water Heater Installation and Operation Manual 94 Notes Notes...
Страница 95: ...Rinnai Tankless Water Heater Installation and Operation Manual 95 Notes Notes...