SAFETY AND REGULATORY INFORMATION

WARNING

DO NOT

 operate this system before reading the manufacturers instructions.

This appliance must be installed, commissioned and serviced by an authorised person in 

accordance with all applicable local rules and regulations.
Access covers of water heating system components will expose 415V wiring and MUST only be 

removed by an authorised person.
This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appliance by a person responsible for 

their safety.
For continued safety of this appliance it must be installed, operated and maintained in accordance 

with the manufacturer’s instructions.
Children should be supervised to ensure they 

DO NOT

 play with the appliance.

The power mains must have a circuit breaker and it must be adequate for unit FLA. If the power 

supply cord is damaged, it 

MUST BE

 replaced by an authorised person in order to avoid a 

hazard. Take care not to touch the power connections or plugs with wet hands.
Care should be taken not to touch the pipe work as it may be HOT!

DO NOT

 place articles on or against this appliance.

DO NOT

 store chemicals or flammable materials near this appliance.

DO NOT

 operate with collectors or covers removed from this appliance.

DO NOT

 activate heat pump unless cylinder is full of water.

NEVER

 use a flammable spray such as hair spray, paint, etc near this unit as this may cause a 

fire.

At the end of the service life of the heat pump water heater and prior to being disposed of, a 

person  qualified  with  refrigerant  handling  must  recover  the  refrigerant  from  the  system.  The 

refrigerant must not be vented to atmosphere. Please call our National Help Line to arrange for 

an inspection.

WARNING

MANDATORY INSPECTION PRIOR TO INSTALLATION

Immediately report any damage or discrepancies to the Supplier of the appliance. This 

appliance was inspected and tested at the time of manufacture and packaging, and released for 

transportation without known damage. Upon receipt, inspect the exterior for evidence of rough 

handling in shipment. Ensure that the appliance is labelled correctly for the gas and electrical 

supply, and/or other services it is intended to be connected to.
For safety and warranty purposes, appliances that may be damaged or incorrect 

MUST NOT

 be 

installed or operated under any circumstances. Installation of damaged or incorrect appliances 

may contravene local government regulations. Rinnai disclaims any liability or responsibility 

whatsoever in relation to the installation or operation of damaged or incorrect appliances.

NOTICE TO VICTORIAN CONSUMERS

This appliance must be installed by a person licensed with the Victorian Building Authority.

Only a licensed person will have insurance protecting their workmanship.

So make sure you use a licensed person to install this appliance and ask for your Compliance Certificate. 

For further information contact the Victorian Building Authority on 1300 815 127

WARNINGS AND IMPORTANT INFORMATION

Содержание CHP3PHAUX

Страница 1: ...3HP Auxiliary Relay Box Operation Installation Manual MODEL CHP3PHAUX ...

Страница 2: ...tallation read this manual thoroughly and gain a full understanding of the appliance to ensure safe and correct use IMPORTANT NOTICE FOR INSTALLERS Please leave these instructions with the end user after commissioning of the system and alert the end user of the content sections Warnings and Periodic Inspection and Maintenance This appliance must be installed in accordance with Manufacturer s Insta...

Страница 3: ...s full of water NEVER use a flammable spray such as hair spray paint etc near this unit as this may cause a fire At the end of the service life of the heat pump water heater and prior to being disposed of a person qualified with refrigerant handling must recover the refrigerant from the system The refrigerant must not be vented to atmosphere Please call our National Help Line to arrange for an ins...

Страница 4: ...7 C Heat pump and auxiliary booster may work simultaneously When ambient temperature falls below 0 C heat pump is deactivated Heat pump won t activate until the ambient temperature reaches above 2 C Only the auxiliary booster will operate until the set point reaches When heap pump is in fault auxiliary booster will operate instead of the heat pump until the set point reaches Auxiliary booster will...

Страница 5: ...elect suitable cable size according to the electric element capacity of the tank Normally each 3 phase auxiliary relay box works with one electric tank AUXILIARY BOOSTER SIGNAL Wire terminals 3 and 4 to heat pump with a minimum 0 75mm2 two core cable provided by installer The cable length should be less than 10 metres POWER SUPPLY TO ELECTRIC TANK Connect all active neutral and earth wires directl...

Страница 6: ...Rinnai 6 3PH Auxiliary Relay Box OIM ELECTRICAL DIAGRAM WIRING DIAGRAMS WIRING DIAGRAMS ...

Страница 7: ...NO MAIN POWER SUPPLY 415V 50Hz SUPPLY TO TANK 415V 50Hz N L1 L2 L3 N GLAND MAIN ISOLATOR 415V 50Hz Auxiliary Contactor Auxiliary Contactor Auxiliary Contactor Electric Tank Electric Tank Electric Tank CHP3PHAUX CHP3PHAUX if provided CHP3PHAUX if provided TO HEAT PUMP TERMINAL 3 4 WIRING DIAGRAMS ...

Страница 8: ...Tel 1800 000 340 Cost of a local call may be higher from a mobile phone National calls from public phones in Australia are free For further information visit www rinnai com au or email enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance If your appliance requires service please call o...