Rinnai 20
Evap AC IM
IMPORTANT
Exhaust fans may be required if insufficient free exhaust area exists. If the exhaust fan is the only
exhaust or ventilation outlet, then its capacity should be at least equal to the Cooler’s air output.
Door = 1.6m²
Hinged Window = 0.3m²
Sliding Window = 0.7m²
Average ventilation area provided by various openings when fully opened.
Model
Number of average size windows & doors
(suggestive only)
Highest
Fan
Setting
Lowest
Fan
Setting
C Series
A Series
C20
A20
Two sliding windows or Five hinged windows
1.5 m
2
0.9 m
2
C30
A30
One door and a hinged window
1.9 m
2
1.1 m
2
C40
A40 / A50
Three sliding windows or one door & two hinged windows
2.3 m
2
1.4 m
2
C50
A60
Four sliding windows or one door and four hinged windows
2.8 m
2
1.7 m
2
C60
A70
Five sliding windows or one door and five hinged windows
3.1 m
2
1.9 m
2
C70
A80
Six sliding windows or one door and six hinged windows
3.4 m
2
2.1 m
2
11. EXHAUST AND VENTILATION