Installation and Operating Instructions for
Brake EV/EH 018/024/028/038 EFM
– 240M/480M
Electromagnetically activated- Spring released
E 09.768e
issue: 23.01.2020
version: 2
drawn.: MAYA
checked.: EISF pages: 23
page: 5
On the brake you can find a name plate with a 16 digit material number. Only with that type num-
ber you can specify the brake.
Please consult the drawings in each section when using this instructions.
As well as these instructions, please also consider the catalogue data for the brake at
www.ringspann.com and the drawings in the individual sections.
2.3 Technical details
EV / EH
018EFM
EV / EH
024EFM
EV / EH
028EFM
EV / EH
038EFM
Clamping force
3200 N
5500 N
12500 N
24000 N
Nominal air gap each side
0,3 mm
0,3 mm
0,3 mm
0,3 mm
Max. friction pad wear
2)
5 mm
5 mm
7 mm
7 mm
Friction pad wear without adjustment
0,3 mm
0,3 mm
0,3 mm
0,3 mm
Clamping force / braking torque
adjustable
1)
60
– 100%
60
– 100%
70
– 100%
70
– 100%
Weight [kg]
6,5 kg
13 kg
24 kg
50 kg
Smallest brake disc diameter
125 mm
250 mm
300 mm
430 mm
type 12,5
Brake disc thickness
type 25
8 to 15mm
16 to 20 mm
10 to 16 mm
18 to 26 mm
10 to 16 mm
18 to 26 mm
12,5 to 20 mm
22 to 30 mm
Type 240V
Supply voltage
1)
Type 480V
220
… 240VAC
380 … 480VAC
220
… 240VAC
380 … 480VAC
220
… 240VAC
380 … 480VAC
220
… 240VAC
380 … 480VAC
Supply voltage frequency
4)
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
Electric fuse
B10, C6
B10, C6
B10, C6
B10, C6
Power consumption „brake closed“
14 W (220-480V)
32 W (380-480V)
20 W (220-480V)
22 W (380-480V)
14 W (220-480V)
19 W (380-480V)
10 W (220-480V)
24 W (380-480V)
Electrical degree of protection
IP 65
IP 65
IP 65
IP 65
Insulation class
PE conductor
PE conductor
PE conductor
PE conductor
Duty cycle
100 %
100 %
100 %
100 %
Max. switching frequency at 20°C
ambient temperature
3)
240 / h
240 / h
240 / h
240 / h
Ambient temperature
3) 5)
-30°C .. +55°C
-30°C .. +55°C
-30°C .. +55°C
-30°C .. +55°C
1)
The nominal value is marked on the type label, and on a sticker on the electronics. There are two
kinds of electronics: 220 … 240VAC and 380 … 480 VAC.
2)
The max. allowable friction pad wear depends on the brake disc thickness. See also chapter 11.2.
3)
Higher ambient temperature as 20°C reduces the max. switching frequency per hour.
4)
No adjustments necessary, the brake can only be used with 50Hz or 60Hz.
5)
At low temperatures below -30°C to -40°C, a reduction in clamping force is necessary. Consultation with
RINGSPANN is necessary.