AUTOMATIC CHARGE STAGE 

Stage 1 - Diagnosis: Analyse if the battery can accept a charge or not, and then prevent charging from proceeding on the a 
defective battery;

Stage 2 - Desulphation: The charger can rescue most drained batteries with voltages up to a Min 1.5±0.5V

Stage 3 - Pre-charge: If the battery voltage is less than 12V, charge it at the smaller current, which will protect the battery better;

Stage 4 - Soft start: Charge the battery to the maximum current gradually and never suddenly.

Stage 5 - CC1/CC2/CC3 (Constant Current): The charger automatically adjusts the current according to the battery status in 
constant current, which benefits the battery for a long life;

Stage 6- CV (Constant Voltage): The battery is charged to nearly full, and will top off at 14.6V DC;

Stage 7 - Resting: The charger will cut off with full charged statement, and achieves the high energy efficiency;

Stage 8 - Recondition: When it is fully charged and low to 12.8V within 2min, the charger will judge automatically.

Stage 9 - Restoring: The charger monitors a fully charged battery automatically. If the battery falls below 12.8V DC, the charger 
will restart from stage 4 to stage 7.

CHARGING

NOTE: Before using the charger, please review all safety and connection directions. Failure to do so can damage battery 
and cause serious injury or death.

 

·  Connect the charger to battery per the operating instructions.

·  Connect the charger to AC outlet.

·  Select the appropriate charging mode for your batteries.

·  If the charger does not detect a properly connected battery, the Reverse Polarity Indicator LED will light or the Error Code will  
 

appear on LCD display until such a battery is detected. Charging will not begin while the Reverse Polarity Indicator LED is on or  

 

the error code disappears. When the charging begins, the charging process Icon on LCD display will appear.

·  When charging is completed, unplug the charger from the AC outlet first and then disconnect the batteries with charger.

Содержание RSC404

Страница 1: ...Instructions Intelligent Battery Charger 6V 12V 4A Suitable for 12V Lead Acid Gel Calcium AGM and EFB batteries between 10 120Ah...

Страница 2: ...c shock unplug charger form outlet before attempting any maintenance or cleaning Turning off controls will not reduce this risk 12 WARNING RISK OF EXPLOSIVE GASES a WORKING IN VICINITY OF A LEAD ACID...

Страница 3: ...or the 6V batteries 5 12V will appear when selecting the charge for the 12V batteries 6 The icon will indicate the charging process 7 The numbers or characters will indicate the battery voltage or the...

Страница 4: ...sheet metal body parts Connect to a heavy gauge metal part of the frame or engine block OPERATING INSTRUCTIONS PREPARING TO CHARGE a If necessary to remove battery from vehicle to charge always remove...

Страница 5: ...into an outlet that is properly installed in accordance with all local codes and ordinances DANGER Never alter AC cord or plug provided if it will not t outlet have proper outlet installed by a quali...

Страница 6: ...Stage 8 Recondition When it is fully charged and low to 12 8V within 2min the charger will judge automatically Stage 9 Restoring The charger monitors a fully charged battery automatically If the batt...

Страница 7: ...arge Reconditioning Function may help reverse the effects of sulphation and restore a batteries ability to accept a charge If the charger detects a sulphated battery it will automatically activate Bat...

Страница 8: ...racking or other damage and have them replaced if necessary 6 WARNING All other service should be done by quali ed personnel only TECHNICAL DATA Model RSC404 Input 220 240V AC 50Hz Output 6V DC 2A 12V...

Отзывы: