Wake-Up Notification

The sensor will wake up every so often to send a Wake-Up Notification to allow the life line master node 
controller that the sensor is now available for any queued messages that the controller may have for 
the sensor. The time between Wake-Up Notifications can be configured with the Wake-Up Notification 
command class to be between 1 and 24 hours with interval steps of 1 minute.

Mapping of the Basic Command Class

The device can be queried with Basic for each of its eight endpoints to see if they are 0 (contact closed) 
or 0xFF (contact open).

Z-Wave Command Class

Command Class

Version

Z-Wave Plus Info

2

Transport Service V2

2

Security 2

1

Association

2

Association Group Info

Multi-Channel Association

3

Multi-Channel

4

Battery

1

Configuration

1

Device Reset Locally

1

Manufacturer Specific

2

Notification

8

Power Level

1

Supervision

1

Wakeup

2

Version

3

Firmware Update MD

4

Firmware Update MD

2