Setup Mode
The inverter can be configured by entering the setup mode
To enter Setup Mode press & hold
key
Press
keys to select item then press
, chosen setting will then flash
Adjust setting using
then press
to set
Press and hold
key to exit back to
Information Mode
Output Voltage
Sets the AC output voltage. Only change if the application requires a different
voltage for optimum performance
Last Error Code
Allows the last error code to be viewed
Battery Size
Sets the Ah rating of the battery supplying the inverter. The value is used when
calculating input current and hours remaining in conjunction with the Current
Sensor
Power Saving Mode If the inverter does not detect a load for 10 minutes it will enter a sleep mode to
reduce drain on the battery. In this mode the power indicator will flash green
Low Voltage Cut-Off Sets the voltage at which the inverter will switch off should the input voltage
become too low
Output Frequency
Sets the output frequency of the inverter. Only change if the application requires a
different frequency for optimum performance
Setting
Default
Output Voltage
200/220/230/240V
230V
Last Error Code
N/A
N/A
Battery Size
90 – 540Ah
(in 30Ah steps)
90Ah
Power Saving Mode
ON/OFF
ON
Low Voltage Cut-off
9-5 – 11.0V
(in 0.5V steps)
10.0V
Output Frequency
50/60Hz
50Hz