Rilon TIG 200PAC/DC GDM Скачать руководство пользователя страница 6

 

4

 

  The  gas  and  fumes  are  harmful  to  health,  please  wear  protective 

device according to regulations. 

  Wear exhaust equipment and breathe preventive facilities to prevent gas poisoning or 

choke.   

  Use suggested part exhaust equipment and breathe preventive facilities to prevent hurt or 

poisoning by gas and other powder, please.   

  To prevent oxygen-deficiency, air out the gas-filled room which is full of CO

2

 and argon on 

the bottom, when operating on trunks, boilers, cabins, etc.     

 

Please accept the supervisor’s inspection when operating in narrow space. Air the room 
and wear breathe preventive facilities.   

  Never operate in degrease, washing or spray space.   

  Using breathe preventive facilities when weld shielded steel for it will cause poisonous dust 

and gas.   

 

 

The arc, spark, residue and noise are harmful to health, please wear 

protective appliance.   

  Eye protection against arc is recommended when welding or supervise welding.   

  Please wear preventive spectacles.   

 

Welder’s gloves, welder’s goggles, long sleeve clothes, leather apron, and other standard 
protection equipments must be worn for welding operation. 

  A screen to protect other people against the arc must be set in the welding place.   

 

 

Please follow the notes below to avoid gas cylinder toppling over or 

broken. 

  Use the gas cylinder correctly.   

  Use the equipped or recommended gaseous regulator.   

  Read the manual of gaseous regulator carefully before using it, and pay attention to the 

safety notes.   

  Fix the gas cylinder with appropriative holder and other relative parts. 

  Never put the cylinder under high temperature or sunshine environment. 

  Keep your face away from the gas cylinder exit when opening it. 

  Put on the gas shield when it is not used.   

  Never put the torch on the gas cylinder. The electrode can not meet the gas cylinder.   

 

 

 

 

Содержание TIG 200PAC/DC GDM

Страница 1: ...TIG 200PAC DC GDM WELDING MACHINE USER MANUAL...

Страница 2: ...after this sign means there is some potential danger which may cause hurt or property lose if it is not followed The words after this sign means there is potential risk which may cause equipment faul...

Страница 3: ...ta 7 3 Installation 8 4 Operation 10 4 1 Front Panel Layout 10 4 2 Operation Instruction 12 4 3 Welding Environment and Safety 16 4 4 Welding Problems and Resolution 17 5 Daily Maintenance and Checkin...

Страница 4: ...narrow space may cause choke Spark and hot workpiece after welding may cause fire Bad connected cable may cause fire Incompletion connection of workpiece side circuit may cause fire Never weld on the...

Страница 5: ...minutes later The capacitance is chargeable device Please ensure it has no voltage before start again even if the power source is cut off Do not use wire with inadequate section surface or damage ins...

Страница 6: ...harmful to health please wear protective appliance Eye protection against arc is recommended when welding or supervise welding Please wear preventive spectacles Welder s gloves welder s goggles long...

Страница 7: ...of the welding equipments and other nearby power cable control cable signal cable and phone cable b Wireless electric as well as TV radiation and reception equipment c Computer and other control equip...

Страница 8: ...that it is easier to design into welding machine with different dynamic characteristics and it even can be adjusted for specialty to make arc softer or harder TIG welding machine is easy for arc init...

Страница 9: ...IG DC 30 TIG AC 36 5 MMA Output current A 15 160 TIG DC 20 180 TIG AC 20 160 MMA Rated working volt V 16 4 TIG DC 17 2 TIG AC 26 4 MMA No load volt V U0 58 TIG MMA Ur 19 MMA Duty cycle 25 TIG 25 MMA A...

Страница 10: ...d connection of shielded gas source Gas supply passage includes cylinder argon decompress flow meter and pipe Connecting part of pipe should use hoop or other things to fasten lest argon leaks out and...

Страница 11: ...ion steps MMA Connect the fast plug of the electrode holder to the socket of terminal on the front panel and fasten it clockwise Connect the fast plug of the earth clamp to the socket of terminal on t...

Страница 12: ...s 3s Open close the VRD function Short press switch the hot start current hot start time arc force current and so on TIG mode Long press 3s switch the 2T 4T and spot mode Short press switch the pre po...

Страница 13: ...time Suitable for TIG AC TIG DC and spot mode Value range 0 9 9s Stop current Suitable for TIG AC TIG DC and spot mode Value range 10 100 Post gas Suitable for TIG AC TIG DC and spot mode Value range...

Страница 14: ...machine Starting up Switch on the machine through the Power Switch the panel will display the previous settings that were saved in the last shutdown Operation instruction under TIG mode Set welding mo...

Страница 15: ...ress the Menu Button for 3s Select the parameters to be set by pressing the Menu Button and then adjusting the parameter value by the Adjustment Knob Adjusting parameters AC frequency Note When the di...

Страница 16: ...sition for a while so that the weld spot could be protected before cooling down for delaying argon Operation instruction under MMA mode Set welding mode Press the Welding Mode Button on the front pane...

Страница 17: ...e MMA mode select the parameters to be set by pressing the Menu Button and then adjusting the parameter value by the Adjustment Knob Adjusting parameters Electrode type Note The configured parameter v...

Страница 18: ...sure the intake is not in block or covered it is 0 3 meter from welding machine to objects of environment User should make sure the working area is adequately ventilated It is important for the perfor...

Страница 19: ...ment that can lower welding quality Arc striking is difficult and easy to pause a Make sure quality of tungsten electrode is high b Grind end of the tungsten electrode to taper If tungsten electrode i...

Страница 20: ...getting moist If any blow and dry Measure the insulation with megohmmeter to make sure it is qualified to use e If the welding machine is not used for a long time pack the machine in original package...

Страница 21: ...element fault Replace the fan If not solve the problem please contact the dealer or contact our company Press the TIG torch switch it has no gas output but has current output The air valve is broken...

Страница 22: ...witch SGDN1 MOT COOL 15V LP CURRENT 3V3 Drive GAS Drive G1 Drive E1 Drive E2 Drive G2 SW _I GND INPUT V PWM_AC 24V POWER EN FBT Drive RW0047 01A_Mcu RW0047 01A_Mcu sch MOT COOL 15V LP CURRENT 3V3 Driv...

Отзывы: