RIKA SYMBIA Скачать руководство пользователя страница 8

8

Stone casing

125

124

123

120

129

122

127

121

128

126

Содержание SYMBIA

Страница 1: ...SYMBIA Operating manual ...

Страница 2: ...e chimney 19 Connecting to a steel chimney 19 Combustion air 19 Feeding in external combustion air 19 6 BRIEF INFORMATION ON COMBUSTIBLE LOGS 20 Suitable fuels and fuel amounts 20 Wood types 20 Output controlling 20 Clean combustion 20 7 MANUAL OPERATION 21 RIKA firelighter 21 Combustion air regulation 21 Correct heating up 22 Nachlegen 22 8 CLEANING AND MAINTENANCE 23 Basic information 23 Cleanin...

Страница 3: ...eful Tip Manually Fragile 10 GUARANTEE CONDITIONS 27 11 WARRANTY CONDITIONS 27 12 DISPOSAL INFORMATION 28 Information on the individual components of the device 28 Extract from the waste code of the European Waste List Regulation 28 Electronic Waste 28 ...

Страница 4: ...r the appliance must be guaranteed at all times Air suction systems can interfere with the combustion air supply The flue gas values of the appliance must be observed for the chimney dimensioning Auxiliary electricity consumption At nominal heat output At minimum heat output Heat output Nominal heat output Minimum heat output Useful efficiency Useful efficiency at nominal heat output Useful effici...

Страница 5: ... 2021 In case of doubt as well as missing or incorrect translations the German version is the only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Andreas Bloderer product management Room temperature control with open window detection Space heating emissions at nominal heat output Space heating emissions at minimum heat ...

Страница 6: ... 18 19 19 13 14 15 16 10 10 11 11 4 3 2 1 11 11 5 5 5 5 5 29 21 6 30 26 22 28 20 20 22 22 23 23 21 21 21 9 8 27 7 54 52 54 52 53 53 53 53 55 55 55 60 60 51 61 50 49 42 42 42 45 41 41 41 41 40 40 40 40 41 41 41 40 40 40 43 43 44 43 46 43 43 43 47 59 57 57 56 56 58 58 59 48 ...

Страница 7: ... 7 6 EN 72 82 87 78 75 73 89 93 94 85 84 83 90 91 70 71 80 79 81 77 86 76 92 88 74 74 109 112 111 107 103 103 106 108 108 104 104 110 105 100 101 113 113 103 104 104 102 102 ...

Страница 8: ...Stone casing 125 124 123 120 129 122 127 121 128 126 ...

Страница 9: ... 9 8 EN Stone casing 188 140 151 151 150 150 152 144 145 137 134 149 147 136 144 148 131 134 133 134 130 144 143 153 141 138 130 135 131 131 133 133 136 137 139 154 188 140 132 ...

Страница 10: ...Stone casing 156 158 157 159 160 161 146 143 136 137 142 143 134 142 134 137 134 149 147 136 144 148 146 134 134 134 148 148 ...

Страница 11: ... 11 10 EN Steelshell 173 172 171 174 175 170 176 177 ...

Страница 12: ...Steelshell 189 187 178 183 182 182 180 180 188 186 184 185 181 202 202 201 201 203 199 200 193 193 185 190 191 194 184 199 196 192 193 182 190 180 190 188 178 199 195 204 ...

Страница 13: ... 13 12 EN Steelshell 207 208 209 212 211 210 184 185 197 185 190 191 194 184 199 196 192 193 197 190 190 190 196 196 ...

Страница 14: ...m front 71 Z37955 Firebrick lining bottom left 72 Z37961 Firebrick lining left 73 Z37806 Firebrick lining left 74 Z37654 Grate laterally 75 Z37807 Firebrick lining rear left 76 Z37861 Firebrick lining rear middle 77 Z37959 Firebrick lining rear left 78 Z37962 Deflection plate top left 79 Z37957 Deflection plate top left 80 Z37956 Deflector plate top 81 Z37958 Deflection plate top right 82 Z37963 D...

Страница 15: ... panel concrete top 160 Z37745 Side casing soapstone left Z37746 Side casing white stone left Z37802 Side casing concrete left 161 Z37737 Side panel soap stone bottom left Z37738 Side panel white stone bottom left Z37798 Side panel concrete bottom left 170 B18766 Cover left 174 LB00846 Cover Nr Art Nr Description 175 LB00749 Top steel front 176 B18767 Cover right 177 LB00907 Bottom steel front 178...

Страница 16: ... temperature C testing Chimney draft requirement Pa 12 The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentation and is to submit it to the authorities or the chimney sweep on request Note Please observe the national and European standards as well as local regulations concerning the installation and operation of firing installatio...

Страница 17: ... to be worn when post heating Q Use the heat resistant gloves supplied to open the doors of your stove Q Only use suitable tools from our range of accessories when handling embers and make sure that no embers fall out of the combustion chamber onto inflammable material Q Push the embers together to form a firebed when you add new fuel logs Q Placing non heat resistant objects on the stove or near ...

Страница 18: ...d with the combustion chamber door closed Q The combustion chamber door may only be opened to add fuel and must then be closed again otherwise other firing installations connected to the chimney may be endangered Q The combustion chamber door is to be kept closed when the stove is not in operation Q Fouling of the chimney i e deposits of highly inflammable materials such as soot and tar and subseq...

Страница 19: ... must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspection and cleaning must be present The flue pipe connection to the chimney has to be air tight Combustion air Every combustion process requires oxygen from the surrounding air This so called combustion air ...

Страница 20: ...ticularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all softwoods and tends to spray sparks Wood type Calorific value kWh m3 Calorific value kWh kg Maple 1900 4 1 Birch 1900 4 3 Beech 2100 4 2 Oak 2100 4 2 Alder 1500 4 1 Ash 2100 4 2 Spruce 1700 4 4 Larch 1700 4 4 Poplar 1200 4 1 Robinia 2100 4 1 Fir ...

Страница 21: ...d humidity of your firewood Ideally one rib is enough to light up the fire Tip You can order the RIKA firelighter with the number E15834 at your RIKA dealer Combustion air regulation The performance of your stove also depends on the chimney draught therefore the control knob for combustion air regulation must be used according to your own experience The heating up position may only be used for hea...

Страница 22: ...inutes later depending on draught fuel quality and amount Nachlegen Note Use the handle Cold Hands or the RIKA heat resistant glove for every further addition of wood After the first burn off add one or two logs see AMOUNT OF FUEL to the blaze Set the control knob to heating up position again until the wood is well lit For optimal combustion the air regulator should be in the ideal position betwee...

Страница 23: ...cold state dispose it of in the household waste Cleaning the combustion chamber Note Only when the stove is cold You could vacuum out embers FIRE RISK The combustion chamber must be regularly cleaned from ash to ensure an adequate supply of air If you remove the grate you can sweep the ashes with a broom in the ash tray You can also use an ash vacuum cleaner Empty the ash drawer Empty the ash draw...

Страница 24: ...aning the flue gas outlet annually Remove the flue pipes Inspect and clean the chimney connection Brush off any soot and dust deposits in the fire and in the flue pipes and vacuum 1 2 I II III I II 1 2 III ...

Страница 25: ...ormance of the stove and pose a safety risk Checking seals annually Check the condition of the seals at least once a year Repair or replace seals depending on condition Note Only intact seals ensure your stove works perfectly Tip You will find the seals in the spare part overview ...

Страница 26: ...ass cleaner Problem 2 Stove smells strongly and or fumes are emitted Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solution s Q Wait to end of burning in phase and vent sufficiently Q Suction off any dust deposits from the convection air openings at regular intervals Problem 3 Flue gas discharge when wood is added and during heating phase Cause s ...

Страница 27: ...tified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a result of an unjustified guarantee claim will be charged back to the claimant Likewise excluded from the guarantee is any damage resulting from or caused by non compliance with the manufacturer s ins...

Страница 28: ...ceramic pane using a suitable tool Remove the seals and separate them from the frame if present Transparent glass ceramic can generally be recycled but must be separated into decorated and non decorated panes The glass ceramic pane can be disposed of as construction waste Q Sheet steel Disassemble the sheet steel components of the device by unscrewing or flexing alternatively by mechanical crushin...

Страница 29: ... 29 28 EN ...

Страница 30: ......

Страница 31: ... 31 30 EN ...

Страница 32: ... only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z38284_SYMBIA_EN 7 12 2021 RIKA Innovative Ofentechnik GmbH Müllerviertel 20 4563 Micheldorf AUSTRIA Tel 43 0 7582 686 41 Fax 43 verkauf rika at www rika at ...

Отзывы: