RIKA REVO II PGI Скачать руководство пользователя страница 11

|11

EN

10

Prior to set up

Floor bearing capacity

Ensure that the substructure is capable of bearing the weight of the 
stove prior to set-up�

Note

No modifications may be made to the firing installation� This also 
leads to loss of warranty and guarantee�

Floor protection

A base is recommended (glass, sheet steel or ceramic) if the floor is 
combustible (wood, carpet, etc�)� Please observe the respective local 
regulations and rules�

Flue pipe connection

 

Q

Flue pipes pose a particular source of hazard regarding gas leaks 
and fire� Get the advice of an authorised specialist company for 
the layout and assembly�

 

Q

Please observe the corresponding installation guidelines for walls 
panelled with wood when connecting your flue pipes to the stove�

 

Q

Observe the formation of flue gas (atmospheric inversion) and 
draughts when the weather is unfavourable�

 

Q

Infeed of too little combustion air can lead to smoke in the rooms 
or to flue gas leaks� Hazardous deposits in the stove and chimney 
may also occur�

 

Q

If flue gas escapes, let the fire burn out and check whether all the 
air inlet openings are free and the flue gas pipes and the stove 
pipe are clean� If in doubt notify the master chimney sweep since 
draught malfunctions may be connected to your chimney�

The correct chimney connection

There are several ways to connect your stove to the chimney, eg:

1) wind break, 2) chimney, 3) inspection opening

For the selection of the connection and to ensure a proper connection 
between the stove and chimney, please read the guide „INSTALLING 
THE STOVE“ or ask your local chimney sweep�

Stoves type 1 (BA 1):

 

Q

Suitable for multiple occupancy� (Note the different country 
regulations�) 

 

Q

These may only be operated with the combustion chamber door 
closed�

 

Q

The combustion chamber door is to be kept closed when the 
stove is not in operation�

 

Q

Fouling of the chimney i�e� deposits of highly inflammable materials 
such as soot and tar and subsequently fire in the chimney may 
occur if the chimney is miscalculated and dimensioned wrong�

 

Q

If this occurs, disconnect the mains plug� Phone the fire brigade 
and get yourself and other residents out of harm’s way�

Note

on ROOM-AIR DEPENDENT and
ROOM-AIR INDEPENDENT OPERATION:

Your pellet stove has been tested as a room-air independent stove 
according to EN14785� It can be operated room air dependent or 
room air independent�

When installed room-air dependent in combination with room-
air installations (e�g� controlled ventilation and venting systems 
(extractors etc�) it must be ensured that the stove and the room 
air system are monitored and safeguarded mutually (e�g� via a 
differential pressure controller)� The combustion air infeed of approx�  
20 m

3

/h must be ensured� 

Please observe the respective local regulations and rules in 
consultation with your master chimney sweep� For changes after 
the printing of this manual, we can not assume any liability� We 
reserve the right to change without notice�

Содержание REVO II PGI

Страница 1: ...PGI only for France Belgium Switzerland REVO II RAO REVO II PGI Operating manual...

Страница 2: ...fety information 10 First heating 10 Safety distances 10 Prior to set up 11 The correct chimney connection 11 4 BRIEF INFORMATION ON FUEL PELLETS 12 What are pellets 12 Wood pellet specification accor...

Страница 3: ...ot daily 17 Cleaning the door glass 17 Cleaning painted surfaces 17 9 CLEANING 18 Cleaning the convection air openings 18 Combustion air intake 18 Cleaning the pellet container 18 Bearings 18 Checking...

Страница 4: ...Spare part overview exploded diagram 34 33 31 36 35 22 22 23 37 20 19 24 32 30 25 26 27 28 29 21 43 48 49 45 40 44 39 38 47 41 42 46 2 1 15 17 8 11 18 9 10 12 13 3 4 6 5 7 14 16...

Страница 5: ...51 51 96 50 50 72 71 70 86 85 83 59 65 79 61 61 64 64 63 63 62 62 75 68 69 66 67 68 69 59 59 78 77 76 59 73 74 82 81 80 92 93 94 95 88 89 90 55 55 55 52 52 52 84 54 56 57 53 54 56 57 88 89 87 54 56 57...

Страница 6: ...5 156 149 151 148 147 146 150 154 153 152 160 161 162 163 165 164 119 120 122 121 123 124 125 115 114 111 110 112 113 126 128 127 108 106 107 104 129 130 133 132 103 104 100 118 117 101 102 105 116 10...

Страница 7: ...2502 Self tapping screw 82 Z35691 Spring plug 83 L03551 Side casing panel back right 84 Z37702 Soapstone right Z37911 Sandstone right Z37705 Stone white right 85 N112134 Self tapping screw 86 Z37910 C...

Страница 8: ...requirement Pa 3 The capacity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firing system is to keep the technical...

Страница 9: ...N13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspection and cleaning must be present The flue pipe connect...

Страница 10: ...g non heat resistant objects on the stove or near it is prohibited Q Q Do not place clothing on the stove to dry Q Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER...

Страница 11: ...1 wind break 2 chimney 3 inspection opening For the selection of the connection and to ensure a proper connection between the stove and chimney please read the guide INSTALLING THE STOVE or ask your...

Страница 12: ...h a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list of monitored fuel manufa...

Страница 13: ...aning cycle The speed of the flue gas fan is increased every hour for a short period to blow ash from the burn pot increasing the operational safety The status indicator CLEAN appears on the display O...

Страница 14: ...hments Select soft bases to prevent scratches to your living space furniture and stove panels Disassembly rear side panel Open the pellet container lid In this position it remains open Remove the 2 he...

Страница 15: ...The stone tilts forwards Lift him carefully up to remove Pay attention to the combustion chamber door Loosen the hexagonal screw only on one side Tilt the stone carefully sidewards and lift him up Rep...

Страница 16: ...ontrol of your stove is to be assumed by an external room thermostat you have to connect your external room thermostat 1 instead of the standard integrated cable bridge 2 The connected room thermostat...

Страница 17: ...flame temperature sensor Remove the dust deposits from the sensor at regular intervals Use a clean cleaning cloth or newspaper Cleaning of the burn pot daily Make sure that the air vents are not block...

Страница 18: ...over the convection fins Combustion air intake If necessary please also clean the air intake with a hoover Note Only when the stove is cold You could vacuum out embers FIRE RISK Cleaning the pellet co...

Страница 19: ...k in false air via incorrectly sealed cleaning covers this air may lead to incomplete combustion in the fire trough and thus piling up of pellets DANGER of FIRE To ensure the proper operation of your...

Страница 20: ...CLEANING and MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Q Burning in phase taking into service Q Q Stove has accumulated dust and or dirt Possible solutions Q Q Wait to e...

Страница 21: ...s These are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important point...

Страница 22: ...aged Serial number Operating instructions Software version Warranty documents Touchdisplay version Door opener Electrical periphery Connection socket earthed GSM modem present Room thermostat present...

Страница 23: ...nuals valid at the time of purchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the clai...

Страница 24: ...one Technical and design changes as well as typesetting and printing errors reserved 2019 RIKA Innovative Ofentechnik GmbH Z38152_REVO II_RAO_PGI_EN 16 09 2019 RIKA Innovative Ofentechnik GmbH M ller...

Отзывы: