RIKA jazz Скачать руководство пользователя страница 18

 

- 18 - 

 

E

N

G

L

IS

H

 

 

 

7 .   W A R R A N T Y  

 

WE GUARANTEE 

 
These  warranty  conditions  are  only  valid  for  the  following 
countries:  Austria,  Germany  and  Switzerland.  Separate 
conditions  imposed  by  the  importer  apply  for  all  other 
countries 
  
For  the  purpose  of  timely  damage  limitation,  the  warranty 
claim  on  the  part  of  the  claimant  is  to  be  enforced  at  the 
RIKA  dealer  in  writing  using  the  invoice  and  stating  the 
purchase date, model name, serial number and reason for 
complaint. 
  
WARRANTY 
  
5 years on the welded stove body. This exclusively applies 
to  defects  in  materials  and  workmanship  as  well  as  free 
replacement.  Labour  and  travel  times  are  not  included  in 
the manufacturer’s warranty. 
  
Only original parts supplied by the manufacturer should be 
used. Loss of warranty on non-observance! 
  
The  precondition  for  the  warranty  is  that  the  stove  has 
been installed and commissioned properly according to the 
User and installation manuals valid at the time of purchase. 
Connection  must  be  performed  by  a  specialist  for  such 
stoves. 
 
Any  costs  incurred  by  the  manufacturer  due  to  unjustified 
warranty claims are to be charged to the claimant. 

 
 
  
 
W e a r   p a r t s  and parts affected by fire are excluded, such 
as glass, coating, surface coatings (e.g. handles, panels), 
seals,  fire  trough,  grates,  draught  plates,  deflector  plates, 
combustion  chamber  liners  (e.g.  fireclay),  ceramics, 
natural  stone,  thermo  stone,  ignition  elements,  sensors, 
combustion chamber sensors and temperature controller. 
 
Damage 

arising 

from 

non-observance 

of 

the 

manufacturer’s instructions for operation of the unit  or any 
damage that is caused by action such as overheating, use 
of  non-approved  fuels,  tampering  with  the  device  or  the 
flue  gas  pipe,  electrical  excess  voltage,  an  incorrect, 
insufficient  or  excessive  flue  draught,  condensation,  non-
performance  or  deficient  maintenance  and  cleaning,  non-
observance  of  the  relevant  and  applicable  building 
regulations,  incorrect operation by the user or third parties, 
transport and handling damage is also excluded. 
  
THE 

WARRANTY 

DOES 

NOT 

AFFECT 

THE 

STATUTORY WARRANTY PROVISIONS. 

Содержание jazz

Страница 1: ... 1 Instruction Manual ...

Страница 2: ... 2 ...

Страница 3: ... 3 D I M E N S I O N S ...

Страница 4: ... 4 S P A R E P A R T O V E R V I E W ...

Страница 5: ...3678 Front door complete B16144 28 Front door Z33656 29 Glass holder Z33893 30 Cable door closure B16147 31 Pulley Z33895 Item Designation Article No 32 Door glass Z33700 33 Hinge complete B16143 B16145 Z3384 Z33774 B16146 Z33897 L01545 Z33898 Z33899 Z33890 Z33887 Z33885 Front door handle complete 35 Wooden handle 36 Lamella rear 37 Cover soapstone 38 Stone holder side panel 39 Side panel soapston...

Страница 6: ... 6 ...

Страница 7: ...n of the stove Connecting the stove 13 Connecting an external combustion air infeed 13 4 Operation Fire lighting 14 Ash drawer 15 Operating the shaker grate 15 Slide control ideal position 15 Functional diagram of slide control 15 5 Maintenance and cleaning General maintenance 16 Surface texture and cleaning 16 Convection air opening 16 Cleaning the flue gas pipes 16 6 Problem solutions What to do...

Страница 8: ...connection to a chimney already used by other stoves for solid or liquid fuels is possible as long as the chimney dimensions do not contradict this according to DIN 4705 Part 3 Exhaust values for multiple use of the chimney according to DIN 4705 or to dimension the chimney according to DIN 4705 Exhaust mass flow 6 4 g s Exhaust temperature 245 1 C Minimum feed pressure at rated useful heat 12 Pa T...

Страница 9: ...f highly flammable or explosive materials such as empty spray cans etc in the combustion chamber and storing them near the stove is strictly prohibited due to the danger of explosion No light or inflammable clothing is to be worn when post heating Placing non heat resistant objects on the stove or near it is prohibited Do not place clothing on the stove to dry Stands for drying clothes etc must be...

Страница 10: ...cted to the chimney may be endangered The combustion chamber door is to be kept closed when the stove is not in operation 1 9 Fouling of the chimney i e deposits of highly inflammable materials such as soot and tar and subsequently fire in the chimney may occur if wet fuel is used and operation is damped too much If this occurs phone the fire brigade and get yourself and other residents out of har...

Страница 11: ... types of wood have different fuel values Deciduous wood is particularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all softwoods and tends to spray sparks Wood type Fuel value Kwh m3 Fuel value Kwh kg Maple 1900 4 1 Birch 1900 4 3 Beech 2100 4 0 Oak 2100 4 2 Alder 1500 4 1 Ash 2100 4 2 Spruce 1700 4 4...

Страница 12: ...GHT QUANTITY OF FIREWOOD AND FIREWOOD DIMENSIONS Too much firewood leads to overheating This stresses the material too much and leads to poor flue gas values Too little firewood or logs being too large means the stove does not reach optimum operating temperature The flue gas values are also poor in this case The right quantity of firewood is For wood 1 8 kg 2 logs 25 cm long per layer guideline fo...

Страница 13: ...nal flue pipes from RIKA for proper connection The connection may not project into the chimney shaft Seal the gap between flue pipe and wall liner with ceramic sealer The installation must conform to the respective safety and building regulations Please contact your master chimney sweep in this context He will be pleased to inform you If you use a system chimney e g glazed fireclay we would ask yo...

Страница 14: ...middle some minutes later The primary air is now closed and the secondary air completely open Set the slide control to ideal position for burn off after some minutes see page 28 for functional diagram of slide control 4 Add approx 1 2 kg wood 1 2 logs after the first burn off depending on the thermal output required Not return the slide control to fire lighting position the primary air is open com...

Страница 15: ...d always remain closed Exception Wood or briquettes are too moist The riddle grate does not have to be operated during heating SLIDE CONTROL IDEAL POSITION Page 18 19 part 38 Fuel Wood wood briquettes Primary air Closed 0 Secondary air 2 3 closed 66 The fire lighting position may only be used for fire lighting and for a few minutes after adding fuel The slide control must be used according to your...

Страница 16: ...s otherwise there is a risk of damage to the glass surface and or inscription RIKA glass cleaner is available from stove dealers Moist firewood may be the cause of excessive sooting of the glass The stove surface is heat resistant and may only be cleaned with a cloth possibly moist Only use original coating for repairs this is available from your specialist dealer Do not clean the coating prior to...

Страница 17: ...ry quickly but burns off again if operation is correct See Maximum fuel quantities See Clean burning possibly use wood briquettes are evenly dry 2 Stove does not draw properly Chimney draught insufficient Stove is sooted over inside See A small study of heating See Maintenance and cleaning 3 Stove does not start burning properly Weather influence Incorrect heating up See Fire lighting See Fire lig...

Страница 18: ...id at the time of purchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant Wear parts and parts affected by fire are excluded such as glass coating surface coatings e g handles panels seals fire trough grates draught plates deflector plates combustion chamber liners e g fireclay...

Страница 19: ... 19 ...

Страница 20: ... 20 G U A R A N T E E G A R A N T I E Customer Client To A Stamp Marque Z33901 2011 12 06 ...

Отзывы: