5. OPERATION – MANUAL REAR WALL

Correct heating up

1. Press the control knob at the rear wall down completely into “Heating-up 

position” – primary and secondary air intakes are open completely in the 

heating-up position. Open the combustion chamber door, place left and right 2 

small pieces of chipboard lengthways in the bottom of the combustion chamber.

Place 2 logs crossways on top of this chipboard.

2. Now place further pieces of chipboard in crossways layers on top of the logs 

and place a firelighter on the left underneath the chipboard (some uncoated 

paper can be placed underneath the chipboard instead of using a firelighter). 

3. Open the riddle grate completely and now light the firelighter (or the uncoated 

paper) and close the combustion chamber door. “Correct heating up” primarily 

counteracts excessive smoke during heating up.

Set the control at the rear wall to middle position some minutes later. The 

primary air intake is now closed and the secondary air intake is completely 

open. The control can be set to ideal position (see CONTROL KNOB REAR WALL) 

another few minutes later (depending on draught and fuel quality / amount).

After the first burn-off, again add approx. 2kg wood (2 logs). Open the riddle 

grate and set the control at the rear wall to “Heating-up position” again until the 

wood is well lit. Further regulation is effected as described in Item 3.

Please proceed in the same way for every further addition of wood.

Note

If a lot of smoke develops when wood is placed on a low firebed, an explosive 

gas/air mixture may arise and cause a deflagration. It is recommended that a 

new heating-up procedure is started for safety reasons.

Operating the riddle grate

The ash is moved from the combustion chamber to the ash drawer by pushing 

the riddle grate handle back and forth. This frees the way for the primary air 

intake which is required for heating up.

The riddle grate can be closed for further wood addition after the heating up.

The riddle grate should always remain closed. Exception: wood or briquettes 

are too wet.

Control knob rear wall

The “Heating-up position“ may only be used for heating up.

The performance of your stove also depends on the chimney draught; therefore 

the control know at the rear wall must be used according to your own experience.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

zero setting

 

0% secondary air

0% primary air

 

 

 

ideal position

 

33-66% secondary air

0% primary air

 

middle position

 

100% secondary air

0% primary air

 

 

 

 

 

 

 

 

Heating-up position

 

100% secondary air

100% primary air

 

Note

The air control seals to 100%. Complete closing of the air regulator (zero 

setting of control knob) during operation poses a hazard of deflagration and 

is strictly prohibited.

A stop to prevent inadvertent closing of the air intake has been integrated for 

safety reasons.

To prevent air intake completely, the control knob at the rear wall must be 

pressed back slightly, only then can the zero position be set and the air 

regulator thus closed. 

Содержание IMPERA

Страница 1: ...IMPERA XL Operating Manual...

Страница 2: ...inal heat output 12 Clean combustion 12 4 INSTALLING THE STOVE 13 General information 13 Connection to the chimney 13 Connecting to a steel chimney 13 Combustion air 13 Feeding in external combustion...

Страница 3: ...ing kW 3 6 4 8 fuel consumption m 70 160 90 210 electric supply kg h bis 1 7 bis 2 3 average electrical input 88 5 90 2 fuse 9 4 11 efficiency mg mN 3 435 431 CO2 mg mN 3 18 19 CO emission on 13 O g s...

Страница 4: ...9 1 1 1 1 1 0 1 0 1 2 1 2 1 3 1 4 1 5 1 6 1 7 1 9 1 8 2 0 2 3 2 2 2 1 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 5 3 4 3 3 3 7 3 6 3 2 3 3 8 3 9 40 41 42 43 43 44 45 46 47 48 49 Spare part overview exploded d...

Страница 5: ...5 4 5 5 5 8 5 9 5 7 5 6 6 0 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 6 9 7 0 7 1 7 1 7 2 7 3 6 9 7 6 7 5 7 7 7 8 7 5 7 4 7 7 7 9 8 0 8 2 8 5 8 3 8 3 8 2 8 4 98 8 3 1 0 0 97 8 1 8 8 8 6 8 6 8 7 8 7 93 94 92 91...

Страница 6: ...rview exploded diagram IMPERA XL 2 7 1 1 1 1 1 2 4 6 8 3 4 3 5 2 4 2 2 5 3 1 3 3 3 2 2 8 3 0 2 9 1 9 1 0 1 0 9 2 3 3 7 2 6 5 2 2 1 0 0 1 5 1 6 1 7 1 9 2 1 1 3 1 4 2 0 1 8 46 3 9 40 45 43 42 3 7 47 3 8...

Страница 7: ...0 6 1 6 3 5 1 49 5 2 5 0 5 7 5 5 5 4 48 5 3 7 4 7 6 7 3 7 2 7 5 6 8 6 7 7 1 6 9 7 0 6 9 7 7 6 7 7 3 7 5 6 6 6 5 7 8 6 4 8 2 91 92 90 8 9 8 9 8 8 99 93 8 7 8 7 8 5 94 97 8 0 8 6 7 9 95 98 8 3 8 3 8 4 8...

Страница 8: ...wood retainer 48 Z31566 grate support left 49 Z35054 fire brick left 50 E15460 front stone soapstone E15461 front stone white stone 51 E15462 steel front 52 Z34860 safety bolt 53 L02302 stone holder 5...

Страница 9: ...t stone soapstone E15464 front stone white stone 49 E15465 steel front 50 Z34860 safety bolt 51 L02209 stone holder 52 N111967 allen screw M06x10 53 B17230 cover rear connection 54 N110017 allen screw...

Страница 10: ...children aware of this particular danger and keep them away from the stove during heating Q Only burn approved heating materials Q The combustion or introduction of highly flammable or explosive mater...

Страница 11: ...g embers and make sure that no embers fall out of the combustion chamber onto inflammable material Q Use the heat resistant gloves supplied to open the doors of your stove Stoves type 1 BA 1 Q These m...

Страница 12: ...els of resin and burns off faster as do all softwoods and tends to spray sparks wood type fuel value kWh m3 fuel value kWh kg maple 1900 4 1 birch 1900 4 3 beech 2100 4 2 oak 2100 4 2 alder 1500 4 1 a...

Страница 13: ...e pipe connection to the chimney has to be air tight Combustion air Every combustion process requires oxygen from the surrounding air This so called combustion air is removed from the living are in th...

Страница 14: ...Item 3 Please proceed in the same way for every further addition of wood Note If a lot of smoke develops when wood is placed on a low firebed an explosive gas air mixture may arise and cause a deflagr...

Страница 15: ...chamber as ash as a residue of the combustion This is an excellent fertiliser for all plants in the garden it is a completely natural product The ash should be stored first and extinguished with wate...

Страница 16: ...vection air openings at regular intervals The stove should be cleaned thoroughly prior to the start of the heating season to prevent excess odour Combustion air air intake Also clean the air intake if...

Страница 17: ...ted flue gas Remove the stove cover by simply lifting Remove the rear panel and cut it out along the perforation Replace the flue outlet to the cooking lid Finally the rear wall and the optional stove...

Страница 18: ...sible solution s Q Wait to end of burning in phase and vent sufficiently Q Suction off any dust deposits from the convection air openings at regular intervals Problem 3 Flue gas discharge when wood is...

Страница 19: ...rchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant Wear parts and parts aff...

Страница 20: ...Ofentechnik GmbH 4563 Micheldorf Austria M llerviertel 20 Telefon 43 7582 686 41 Fax DW 43 E Mail verkauf rika at RIKA AT Technical and design changes as well as typesetting and printing errors reserv...