RIKA Espirit Скачать руководство пользователя страница 2

 

 

TABLE OF CONTENTS 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INSTALLATION AND ASSEMBLY 

 

Austroflamm: An Overview 

Safety Precautions 

Labels 7 
EPA Certification Information 

Parts Illustration 

Installation Instructions 

11 

 Clearances 

12 

 Chimney 

Configurations 

14 

 

Existing Masonry Chimney 

16 

 

OPERATING INSTRUCTIONS / FEATURES 

 

General Operation 

21 

 

MAINTENANCE AND CLEANING 

 

Maintenance and Cleaning 

23 

 

MISCELLANEOUS 

 
User Notes 

25 

 

WARRANTY 

 
Warranty 26 
Warranty Registration Card

 

27 

 

 
 
 
The Esprit Wood Stove has been tested to 
and in compliance with UL-1482 and ULC-
S627 (the safety listing label is on the back 
of the stove.)  

 

Tested and Listed by 

 

OMNI-Test Laboratories, Inc. 

Beaverton, Oregon 

SAFETY NOTICE

 

IF THIS WOOD STOVE IS NOT 
PROPERLY INSTALLED, A HOUSE FIRE 
MAY RESULT.   
 
FOR YOUR SAFETY AND TO REDUCE 
THE RISK OF FIRE, FOLLOW THE 
INSTALLATION DIRECTIONS.

  

 

CONTACT LOCAL BUILDING OR FIRE 
OFFICIALS ABOUT RESTRICTIONS AND 
INSTALLATION INSPECTION 
REQUIREMENTS IN YOUR AREA. 

 

PLEASE READ THIS ENTIRE MANUAL 
BEFORE INSTALLATION AND USE OF 
THIS WOOD BURNING ROOM HEATER.  
 
FAILURE TO FOLLOW THESE 
INSTRUCTIONS COULD RESULT IN 
PROPERTY DAMAGE, BODILY INJURY 
OR EVEN DEATH.

 

 
SAVE THESE INSTRUCTIONS FOR 
FUTURE REFERENCE 
 

WARNING 

THIS STOVE IS NOT INTENDED FOR 
USE IN COMMERCIAL 
APPLICATIONS. 
  
THIS STOVE SHOULD BE INSTALLED 
BY AN AUTHORIZED SERVICE
TECHNICIAN. 
 
THIS STOVE IS NOT DESIGNED FOR 
USE IN A MOBILE HOME. 

Содержание Espirit

Страница 1: ...1...

Страница 2: ...ove Tested and Listed by OMNI Test Laboratories Inc Beaverton Oregon SAFETY NOTICE IF THIS WOOD STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY AND TO REDUCE THE RISK OF FIRE F...

Страница 3: ...toves available in today s marketplace Unique designs and emphasis on quality performance and superior workmanship have made us a leading stove manufacturer in Europe State of the art processes such a...

Страница 4: ...annual basis HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY FROM STOVE DO NOT TOUCH ANY RADIANT SURFACE OF YOUR STOVE CONTACT WITH STOVE MAY CAUSE SKIN BURNS DO NOT COOK FOOD HOT BEV...

Страница 5: ...ve heat output could exceed design and safety limits of the appliance This may result in damage to the appliance a house fire other personal property damage personal injury or death DO NOT OPERATE YOU...

Страница 6: ...n the general vicinity of the stove If fumes become excessive open a windows and or door and use a room fan to create cross ventilation Hardening of the finish will be complete after several hours of...

Страница 7: ...7 OMNI SAMPLE LABEL FOR ESPRIT FREESTANDING WOOD STOVE...

Страница 8: ...8 EPA CERTIFICATION INFORMATION...

Страница 9: ...Z21351 shaker grate 4 108687 screw for shaker grate 5 Z28458 shaker grate actuator 6 Z20467 shaker grate lever 7 B15687 tiered baffle system 8 L00853 upper fire brick holder left 9 L00852 upper fire...

Страница 10: ...205 fire brick left side 18 Z20215 fire brick left base 19 Z20216 fire brick left rear 20 Z20216 fire brick right rear 21 Z33205 fire brick right side 22 Z20215 fire brick right base 23 Z20214 fire br...

Страница 11: ...CSA CAN B365 Installation Code for Solid Fuel Burning Applications and Equipment These standards are the basis for many national codes They are nationally recognized and are accepted by most local aut...

Страница 12: ...5 16 13 18 all clearances are in inches ALCOVE CONFIGURATION Connector Pipe A B C D E F Double Wall 64 30 24 5 16 10 10 5 Single Wall 72 38 24 5 16 17 17 5 all clearances are in inches TOP VENT OUT T...

Страница 13: ...5 16 24 5 16 na na all clearances are in inches REAR VENT OUT THE BACK Connector Pipe A B C D E F Double Wall na 8 24 5 16 na na Single Wall na 10 24 5 16 na na all clearances are in inches REAR VENT...

Страница 14: ...ire stops where needed or required insulation shield roof flashing chimney cap etc Maintain proper clearance to the structure as recommended by the manufacturer and or local building codes The chimney...

Страница 15: ...sure that the sections do not separate For best performance the chimney connector should be as short and direct as possible with no more than two 90 elbows The maximum horizontal run is 36 and a recom...

Страница 16: ...HIMNEY CONFIGURATIONS There are five allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall NFPA Standard 211 allows the following wall pas...

Страница 17: ...e liner See METHOD A diagram 2 Using a 6 152 4 mm inside diameter listed factory built Solid Pak chimney section with insulation of 1 25 4 mm or more build a wall pass through with a minimum 9 228 6 m...

Страница 18: ...ure the metal chimney connector do not penetrate chimney flue liner See METHOD C diagram 4 Start with a solid pak listed factory built chimney section at least 12 304 mm long with insulation of 1 25 4...

Страница 19: ...nnected to a masonry chimney except for Method B must extend through the wall pass through system to the inner face of the chimney flue but not beyond It does not have to be fastened in place as long...

Страница 20: ...tial chimneys must be enclosed where they extend through closets storage areas or habitable spaces where the surface of the chimney could come into contact with people or combustible materials Chimney...

Страница 21: ...t A short hot fire will help clean off much of the normal soot buildup Using dry well seasoned firewood will help keep the glass soot free Fire Brick The firebox in your woodstove comes with a layer o...

Страница 22: ...the stove should be avoided it is important to supply it with sufficient fuel to maintain a moderately hot fire This aids in reducing the buildup of creosote in the chimney and aides in minimizing so...

Страница 23: ...vely cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ig nited this creosote makes an extremely hot fire The chimney and chimney connector shou...

Страница 24: ...t material in your stove Do not use other type of gaskets If any gasket material in your stove needs to be replaced contact an authorized RIKA dealer for repairs To replace the gasket make sure the fi...

Страница 25: ..._______________ ______________________________________________________________________________________ ______________________________________________________________________________________ __________...

Страница 26: ...d date of installation 4 Serial number of the stove 5 Nature of defect malfunction or complaint Arrangements will be made for inspection If the inspection indicates that the failure was due to defecti...

Страница 27: ...warranty coverage For your convenience a warranty registration card similar to the one pictured in the example on this page is provided for registering the purchase of your new wood stove The actual w...

Страница 28: ...28...

Отзывы: