background image

RIGOL

 

Installation Guide for 

RM-DS-1

 Rackmount Kit

                                                                                                                             

5

 

Installation Instructions

 

 
This section will introduce you how to mount the DS1000 series Oscilloscope into a standard 19-inch 
machine cabinet. 

 
 

Installation Tools

 

 
Table 2 Installation Tools List 

NO. 

Name 

Description 

Phillips screwdriver 

PH2 Phillips screwdriver 

 

 
 

 

CAUTION     

Only authorized personnel can perform the installation, improper operation may cause   
damage to the instrument or incorrect installation. 

 

 
 

Installation Procedures 

 

1.

 

Install the left and right plate: aim the detents of both right and left plate at the openings on 
support board and insert selectively, then fix them using four M4 bolts.   

 

Figure 4: Installation of Left and Right Plate

 

 

Содержание RM-DS-1

Страница 1: ...RIGOL Installation Guide RM DS 1 Rackmount Kit DS1000 Series DS1000CA Series DS1000E Series DS1000D Series Digital Oscilloscope May 2009 RIGOL Technologies Inc...

Страница 2: ...ogies Inc reserves the right to modify or change parts of or all the specifications and pricing policies at company s sole decision Information in this publication replaces all previously correspondin...

Страница 3: ...ctices that could result in damage to this product or other property Terms on the Product These terms may appear on the product DANGER indicates an injury or hazard that may immediately happen WARNING...

Страница 4: ...Qty Part Number Description 1 1 Front Panel 1 RM DS 1 01 1 2 Support Board 1 RM DS 1 02 1 3 Left Plate 1 RM DS 1 03 1 4 Right Plate 1 RM DS 1 04 1 5 Rear Fixed Belt 1 RM DS 1 05 1 6 Rear Fixed Bracket...

Страница 5: ...quirements must be fulfilled by the machine cabinet in which the instrument is mounted 1 The machine cabinet should be a standard 19 inch 2 At least 4U spaces 177 8mm have to be provided by machine ca...

Страница 6: ...Name Description 1 Phillips screwdriver PH2 Phillips screwdriver CAUTION Only authorized personnel can perform the installation improper operation may cause damage to the instrument or incorrect inst...

Страница 7: ...te fixed and fix them using six M4 bolts Figure 5 Installation of Front Panel 3 Place the instrument first put the instrument onto the support board and then generally slide it into right position dow...

Страница 8: ...ix both the rear fixed brackets and rear fixed belt on the support board in connection with the instrument Figure 7 Fix the instrument 5 Loading into machine cabinet mount the rack with instrument fix...

Страница 9: ...ng holes for rack Figure 9 Holes for rack 2 The rack has a power cord that was connected with the power input terminal and the power source terminal in series A ship type switch is used to turn ON or...

Страница 10: ...all Tel 86 10 8070 6688 Fax 86 10 8070 5070 Service Support Hotline 800 810 0002 9 00 am 5 00 pm from Monday to Friday Or by e mail service rigol com Or mail to RIGOL Technologies Inc 156 CaiHe Villag...

Отзывы: