![Rigol DSG5000 Series Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/rigol/dsg5000-series/dsg5000-series_programming-manual_1460929015.webp)
•
When the frequency offset is not 0 Hz, the output frequency is determined by
the setting frequency and frequency offset. The three parameters satisfy the
equation: setting frequency (display frequency) = output fre frequency
offset. You can query or set the RF frequency offset by using the
Return Format
The query returns the RF frequency of the specified channel.
Example
:RF2:FREQ 4MHz /*Sets the RF frequency of CH2 to 4MHz.*/
:RF2:OFFS? /*The query returns 4000000Hz.*/
3.1.1.2
[:SOURce][:RF]:FREQuency:OFFSet
Syntax
[:SOURce][:RF
<
channel>
]:FREQuency:OFFSet
<
freq>[<unit>]
[:SOURce][:RF
<
channel>
]:FREQuency:OFFSet?
Description
Sets the RF frequency offset of the specified channel.
Queries the RF frequency offset of the specified channel.
Parameter
Name
Type
Range
Default
<channel>
Discrete
1|2|3|4|5|6|7|8
1
<freq>
Real
-49 GHz to 49 GHz
0 Hz
<unit>
Discrete
Hz|kHz|MHz|GHz
Hz
Remarks
•
When <freq> is set in "Number" form, the default unit is Hz. For example,
20000. Besides, <freq> can also be set in " Unit" form, For example,
20kHz.
•
The default unit of the return value is Hz.
Command System