Rigol DS8000-R Series Скачать руководство пользователя страница 1

 

 

Service Guide 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DS8000-R Series Digital Oscilloscope

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

Jul. 2020 

RIGOL

 TECHNOLOGIES CO., LTD. 

 

Содержание DS8000-R Series

Страница 1: ...Service Guide DS8000 R Series Digital Oscilloscope Jul 2020 RIGOL TECHNOLOGIES CO LTD...

Страница 2: ......

Страница 3: ...s subject to change without notice RIGOL shall not be liable for either incidental or consequential losses in connection with the furnishing use or performance of this manual as well as any informatio...

Страница 4: ...operators Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and markers on the instrument and check your manual for more information about ratings before connecting the in...

Страница 5: ...of the instrument clean and dry Prevent Electrostatic Impact Operate the instrument in an electrostatic discharge protective environment to avoid damage induced by static discharges Always ground both...

Страница 6: ...ss of important data Safety Terms on the Product DANGER It calls attention to an operation if not correctly performed could result in injury or hazard immediately WARNING It calls attention to an oper...

Страница 7: ...con to enter the Utility menu first and then clicking the System menu item Content Conventions in this Manual DS8000 R series includes the following models Unless otherwise specified this manual takes...

Страница 8: ...l Cover 4 Disassemble the Hanging Ear 5 Disassemble the Front Panel Assembly 6 Disassemble the Metal Front Panel 7 Disassemble the Probe Board 8 Disassemble the Fan Components 9 Disassemble the Main B...

Страница 9: ...mbling the instrument Please use proper tools and follow the correct steps Take care not to deform the metal structure or get hurt when disassembling the metal structures To avoid causing damage to th...

Страница 10: ...please follow the procedures and take care not to scratch the surfaces of the instrument This manual mainly introduces the disassembly and assembly methods for the DS8000 R series digital oscilloscop...

Страница 11: ...er Cord Connector 16 1020004762 1 Mylar Film 17 1010005841 2 BeCu Fingerstock Slot Mount 2 18 1020004774 23 M3x6 Torx Flat Head Countersunk Screw 19 2010004759 1 Interface Board 20 1020000619 2 BNC Nu...

Страница 12: ...ver Figure 1 1 Disassemble the Metal Cover Part Description 6 screws M3x6 torx flat head countersunk screw used for fastening the metal cover Disassembly Steps 1 Use the T10 screwdriver to remove 6 sc...

Страница 13: ...e the Hanging Ear Part Description 6 screws M3x6 torx flat head countersunk screw used for fastening the two hanging ears not all screws are indicated in the above figure Disassembly Steps 1 Use the T...

Страница 14: ...4 Disassemble the Front Panel Assembly Part Description 2 screws M3x6 torx flat head countersunk screw used for fastening the front panel assembly Disassembly Steps 1 Use the T10 screwdriver to remov...

Страница 15: ...gure 1 5 Disassemble the Metal Front Panel Part Description 4 screws M3x6 torx pan head combination screw used for fastening the metal front panel Disassembly Steps 1 Use the T10 screwdriver to remove...

Страница 16: ...obe Board Figure 1 6 Disassemble the Probe Board Part Description 5 screws M3x6 torx flat head countersunk screw used for fastening the probe board Disassembly Steps 1 Use the T10 screwdriver to remov...

Страница 17: ...at head countersunk screw used for fastening the fan components Disassembly Steps 1 Use the T10 screwdriver to remove 4 screws that secure the fan component 2 Take off the fan components gently Tip Wh...

Страница 18: ...combination screw used for fastening the main board Disassembly Steps 1 Use the T10 screwdriver to remove 3 screws that secure the main board 2 Use the T10 screwdriver to remove 12 screws that secure...

Страница 19: ...ndicated in the above figure Disassembly Steps 1 Use the T10 screwdriver to remove 4 screws that secure the isolation board 2 Take off the isolation board gently 3 Use the 5 mm hexagon wrench socket t...

Страница 20: ...3 screws used for fastening the SMA cable Disassembly Steps 1 Use the 8mm hexagon wrench socket to remove 3 screw that secure the SMA cable 2 Remove the SMA cable gently Tip Before disconnecting the S...

Страница 21: ...ion screw used for fastening the interface board Disassembly Steps 1 Use the T10 screwdriver to remove 4 screws that secure the interface board 2 Take off the interface board gently Tip Before disconn...

Страница 22: ...00 R Service Guide Assembly Procedures The assembly procedures are simply the reversal of the disassembly procedures Check whether the cables are correctly connected and whether all the screws are ins...

Страница 23: ...you can connect the probe compensation output signal to the faulty channel to locate the problem and then determine whether the channel or the item to be tested has a problem 3 Resample the signal 3 T...

Страница 24: ...nue to operate the instrument Besides regular test and calibration should be performed to ensure the accuracy of its performance 4 Arrange the instrument properly after you complete the operation 5 Ke...

Страница 25: ...do not expose it to caustic liquids WARNING To avoid short circuit resulting from moisture or personal injuries ensure that the instrument is completely dry before connecting it to the power supply En...