Rigel usb-nSTEP Скачать руководство пользователя страница 2

usb-nSTEP MAC Instructions 

Copyright Rigel Systems 2010 

Page 2 of 2 

www.rigelsys.com 

 

Temperature Compensation 

  
This function runs the temperature internally to the nSTEP so a 
user can actually configure it and then exit the ASCOM driver, 
the nSTEP will keep on 'auto' compensating. 
 
This internal temperature compensation is -not- controlled by 
the higher level ASCOM API for temperature compensation, the 
higher level API uses the temp comp of the ASCOM driver. 

The 

internal compensation should not be used if the higher level 
API's are used.

 

Temp Change:

 

T

his is the temperature change x10 to trigger a compensation. 

The nSTEP uses a fixed point value here which is 10X the real 
temperature change desired. Examples: -005 = move in "-" 
direction when temp changes by 0.5C, +015 = +1.5C change 
must be detected before triggering a compensation. The values 
can range from -100 (-10.0C) to +100(+10.0C) in increments of 
5(0.5C). The sign signifies whether to move + or - steps on a 
change. 

Temp move: 

 

Move this many steps for each Delta Temp change.  Direction of 
movement controlled by sign of DeltaTemp 

Temp Blash: 

Apply this number of steps in last move direction before 
reversing direction. Range 0 through 100 with 0 = no backlash 
takeup 

Temp Timer: 

Temperature will be averaged over this number of seconds. 
Range 1 to 75 seconds. Set to a lower value for more 
immediate changes. A lower value may cause 'hunting' if the 
sensor is detecting a value that is just toggling slightly (e.g. from 
17.5C to 18.0C to 17.5C). 

 

TC Off

  

Internal compensation turned off. 

TC Manual  

Temperature compensation done once on demand. Mutually 
exclusive with the ASCOM drivers temperature compensation. 

TC Auto 

Internal compensation runs all the time.  Mutually exclusive with 
the ASCOM drivers temperature compensation. 

TC Prime 

Must press 

'Prime for Manual'

 then 

'SaveT'

 to set the device's 

current temperature and position so it knows where to start 
from. After that, press SaveT while 

'Manual'

 is set to force a 

compensation at the current temperature. Useful for focusers 
with backlash when you do not want compensation running  in 
the middle of an exposure as taking up the backlash will throw 
image out of focus even more if direction of motion reverses. 
 

 
 
 
5 Year limited warranty: Rigel Systems, 26850 Basswood 
Ave, Rancho Palos Verdes CA, 90275 

warrants to the 

original consumer purchaser of its product that the product will 
be free of defects in material or workmanship 5 years from the 
date of purchase under normal use. During this warranty 
period, 

Rigel Systems 

will, at its option, repair or replace the 

product without charge for parts or labor when delivered to 

Rigel Systems 

with proof of the date of purchase and a 

statement of the problem with the product.  Shipping and 
handling charges to 

Rigel Systems

 are your responsibility. 

This warranty does not apply if the product has been altered or 
repaired by anyone other than 

Rigel Systems 

or has been 

subjected to purchaser abuse, accident, negligence or damage 
subsequent to purchase including battery damage to product. 
This warranty excludes incidental or consequential damages 
resulting from the product or use of the product.  The product 
is not a toy.  Keep away from children. 
 

For more information visit 

http://www.rigelsys.com

 

 