R41Z-EVAL User Guide
Rev 2.0
12
6.1.2
Power Configuration Switch
The power configuration switch allows easy and quick adjustment of most power settings on the R41Z
Evaluation Board.
Figure 17
–
Power Configuration Switch
Power Configuration Switch
SW
Position
Default
Option
1
Bypass Power Mode
DC-DC Power Mode. Buck Mode by default;
Boost mode selectable with Power
Configuration Jumpers. See
2
PSWITCH OFF. When in Buck Mode,
the DC-DC converter will not start
when power is applied. Use this
option when using Bypass Mode.
PSWITCH ON. When in Buck mode, the DC-DC
Converter will automatically start when power
is applied. Use this option when using Boost
Mode.
3
Regulator On. When USB is
connected, the LDO regulator will
supply power to the Evaluation
Board.
Regulator Off. When USB is connected, the LDO
regulator will not supply power.
4
Regulator 3.6V. When USB is
connected, the LDO regulator will
output 3.6V. With the reverse
protection diode, 3.3V is applied to
the R41Z.
Regulator 1.8V. When USB is connected, the
LDO regulator will output 1.8V. With the reverse
protection diode, 1.5V is applied to the R41Z.
Useful for using Boost mode.
Table 3
–
Power Configuration Switch Options