RIFT Actuators RIFT 400 Скачать руководство пользователя страница 4

Version 1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

INTRODUCTION, STORAGE, AND SAFETY INFORMATION:

 

 

INTRODUCTION

 

The RIFT® 400 Actuator is the first commercial 

RIFT DRIVEN

® 

product and is also the first Electric 

Valve Actuator that can be configured to offer either the functionality of a part

-

turn electric valve    

actuator, a direct acting solenoid or that of a multi

-

turn actuator. Correctly applied, configured,         

installed, connected, commissioned and used the RIFT® 400 will provide trouble

-

free, reliable and     

extremely energy efficient service. Energy consumption will be reduced by approximately 75%. This 
actuator is sold as an up to 400Nm  part turn electric actuator with the ability to upgrade its default 
settings and features with the minimum disruption to the client or customer.

 

 

These IOM

s (Installation, Operation & Maintenance Instructions) are provided to offer advice and  

information to installers and users of the RIFT® 400 to achieve reliable and trouble

-

free service.  The  

following symbols are used to indicate warnings:

 

Yellow warning triangle advises actions that MAY cause incorrect operation and non

-

adherence 

to the warnings COULD result in product failure and potential personal injury and/or                        
consequential damage.

 

Red warning triangles advise actions that WILL cause incorrect operation and that non                        
adherence to the warnings WILL result in product failure and potential personal injury and/or 
consequential damage.

 

 

STORAGE

 

Store in a well

-

ventilated and dry room. Actuators should be stored off the floor, either on a shelf or on a wooden 

pallet, for example. Replace supplied transit plastic cable entry plugs with solid plugs and PTFE thread tape.

 

 

Do not store the Actuators with the covers or cable entry plugs removed, as no responsibility will be            
accepted for on

-

site deterioration caused by the covers being removed.

 

 

SAFETY INFORMATION

 

 

All personnel working with the RIFT® 400 must be familiar with this Installation, Operation & Maintenance          

instructions, and the safety recommendations are to ensure correct functionality of the 

RIFT® 400 

Electric              

Actuator and to avoid personal injury or property damage that could occur from non

-

compliance to these               

instructions and recommendations.

 

 

Always ensure that an electric actuator is completely isolated before removing the lid to carry out any 

internal inspection or work. When connected electrically the 

RIFT® 400 

is capable of carrying lethal                     

voltages.

 

 

 

RIFT®  400 

Electric  Actuators  operate  with  the  use  of  live  electricity.  Only  qualified  electricians  or            

people  instructed  in  accordance  with  electrical  engineering,  and  familiar  with  local  electrical                
Installation  requirements  and  health  and  safety  directives  should  be  involved  in  the  connection  of 
these actuators.

 

Содержание RIFT 400

Страница 1: ...Version 1 2 1 VERSION 1 2 INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS RIFT 400 Sub Sea Actuator...

Страница 2: ...OLENOID 7 CONFIGURING AS A MULTI TURN ACTUATOR 8 CONFIGURING AS A MULTI TURN ACTUATOR CONTINUED 8 CONFIGURATION AND CONNECTION WITH ANDROID 8 PAIRING RIFT WITH ANDROID 8 RUNNING THE ANDROID APP 8 UPDA...

Страница 3: ...ON FAILURE TO OPERATE 18 OVER TORQUE INDICATION 18 3 WAY BALL VALVES DEFAULT FLOW PATTERNS 19 3 WAY BALL VALVES DEFAULT FLOW PATTERNS CONTINUED 19 BLUETOOTH 19 BATTERY FAILSAFE FUNCTION BFS 20 METHOD...

Страница 4: ...correct operation and that non adherence to the warnings WILL result in product failure and potential personal injury and or consequential damage STORAGE Store in a well ventilated and dry room Actuat...

Страница 5: ...at the bolts do not reach the solid bottom of the threaded fixing before the bolt is tight against the valve flange Ensure that the valve is in the same position as the actuator when assembling the va...

Страница 6: ...n as the angle for the Closed position and adjust it as so PROCEDURE TO USE CALIBRATION MODE TO MOUNT TO A ISO 5211 FLANGE MOUNT a Move the actuator to the closed position b Mount the RIFT 400 actuato...

Страница 7: ...nt to solenoids the RIFT 400 introduces end of travel confirmation local controls and torque protection and as an extra cost option speed control Note Thermostatic Anti condensation Heaters These are...

Страница 8: ...0317 1177 select the Actuator you wish to pair with Enter the default pairing code 1234 the actuator should be displayed under the Paired Devices list RUNNING THE ANDROID APP Open the App this will ta...

Страница 9: ...ware Version Displays the version of the firmware flashed onto the RIFT 400 App Version Displays the version of the App you are running Valve Orientation Set the valve orientation of the valve stem 45...

Страница 10: ...ted to Torque Limit Back off allows the user to specify the angle that the actuator will back off if the Torque Limit is reached The RIFT 400 Actuator will display an Orange on the top indicating that...

Страница 11: ...l feed back the actual RIFT 400 Actuator position in either 0 10v or 0 4 20mA respective to the control signal input Volt free switch connection is connected through pin 1 0 10v and pin 2 0 10v on the...

Страница 12: ...are not easily assessable We advise additional external battery storage is available to prolong operations on a predetermined cycle WIGGLE This function will allow the RIFT 400 Actuator to be programm...

Страница 13: ...s on Pins 1 4 See page 15for wiring diagram Follow the wiring diagram appropriate to your functional requirement to ensure the correct connection of power and control signaling to the RIFT 400 actuato...

Страница 14: ...0 pin connector supplied is used via the left entry and the right entry connected with 5 core cable onto the 5 pin connection block fitted for the command signals If the end of travel confirmation rel...

Страница 15: ...FT 400 actuator either or make minor setting adjustments Soft reset of the electronics similar to the Ctrl Alt Del under Basic Settings option on the Android App only Reset Board Without Changing Sett...

Страница 16: ...is awake Displaying in the open position Displaying in the closed position The RIFT 400 is now ready to either start functioning as an ON OFF reversible electric actuator It is helpful in an emergency...

Страница 17: ...returning the actuator to normal remote control selected position If it is essential that the actuator moves to a pre determined position upon external power failure you must select and configure the...

Страница 18: ...t the actuator but also the valve is fitted onto within its operational torque bands If the maximum torque is exceeded through either blockage or trying to exceed the operational design the LED s on t...

Страница 19: ...where applicable by selecting using the relevant buttons on the screen of your Bluetooth device e g OPEN and clicking or physically touching the Pad on the RIFT 400 Please note that some parameter ch...

Страница 20: ...RTIONAL CONTROL FUNCTION Electronic Positioning System EPS The RIFT 400 can be Bluetooth configured to select modulating control see page 9 for using Bluetooth with the RIFT 400 For modulating control...

Страница 21: ...rs only and will not control the movement of the Valve Actuator when Analogue Signal Control is selected this is primarily used as a charging circuit Unnecessary frequent movement instigated by a cons...

Страница 22: ...ftware Updates and or New Features DEFINITIONS ABBREVIATION Definitions Abbre viation Explanation AC Alternating Current DC Direct Current PCD Pitch Circle Diameter LCM Local Control Mode PID Proporti...

Страница 23: ...sion 1 2 23 DOCUMENT REVISION TABLEDOCUMENT REVISION TABLE Date Name Revision Details 25 10 2019 Brown 1st revision for RIFT 400 Sub Sea and Android App 06 05 2020 Fabio Musio Change all SmartAct to R...

Отзывы: