background image

WIRELESS PASSIVE INFRARED 

DETECTOR

«PYRONE-SH2-RK»

1 General Information

1.1 

Wireless 

passive 

infrared 

detector 

«Pyrone-SH2-RK» 

(hereinafter,  the  Detector)  is  designed  for  detecting  intrusion  into 
the  protected  closed  hazardous  area  of  a  room  through  door  and 
window openings, for generating and transmitting alarm messages to 
the  control  panel  (hereinafter,  CP)  via  two-way  wireless  channel  by 
the «Rielta-Contañt-R» protocol.

1.2 The Detector provides vertical curtain detection zone.
1.3 The Detector ensures supervision of two-wired loop (hereinafter, 

Loop) with hooked up external detectors.

1.4 The detector can put in operation in two-channel or one-channel 

mode. In the second variant the Loop state is bypassed. The mode is 
chosen at the stage of the Detector logging in the CP.

1.5 The Detector operates within 433.05 – 434.79 MHz frequency 

range. Transmission power does not exceed 10 mW.

1.6  For  radio  signals  exchange  with  the  CP,  the  Detector  ensures 

operation  at  the  main  and  backup  operating  frequencies.  The 
changeover to backup operating frequency is fulfilled automatically.

1.7 Radio communication is initiated by the Detector at 10, 15, 30 sec, 

1, 5, 10 min intervals assigned in the process of their binding with the 
CP. Alarm and tamper messages are transmitted immediately.

1.8 The Detector is powered from the CR123A lithium power supply 

battery.

1.9  The  states  of  the  Detector  are  displayed  by  a  two-color  LED 

indicator.

1.10  The  Detector  provides  the  temperature  compensation  of 

detectability.

1.11 The Detector generates and transmits the following messages 

via radio communication:

-  «Norm  in  zone  1»  –  under  the  movement  absence  within  the 

detection zone;

- «Norm in zone 2» – under the Loop resistance value in the limits 

3.7 – 6.5 k

;

-  «Intrusion  to  Zone  1»  –  under  the  human  movement  within  the 

detection zone limits, transverse to the detection zone side boundary 
within the speed range from 0.3 to 3 m/sec at the distance up to 3m;

- «Intrusion to Zone 2» – under resistance value in «Loop 2» 6.9 k

 

or more or less than 3.4 k

;

-  «Tamper»  –  in  the  event  of  case  tampering  ensuring  access  to 

the PCB;

-  «Power  Supply  Low  Battery»  –  under  the  power  supply  battery 

voltage drop over 2.4

-0.4

 V.

1.12 The Detector is designed to operate continuously, around the 

clock. 

1.13 The Detector has immunity to electromagnetic interference. 

2 Specifications

Table 1

Parameter

Value

Maximum mounting height, m

Detection angle

90

-2

°

Monitored Loop resistance range, k

:

- in «Norm in Zone 2» state
- in «Intrusion to Zone 2» state

3.7 ¾ 6.5

below 3.4 or above 6.9

Operating temperature, °Ñ

from minus 20 ¾ +50 

Relative humidity at +35 °Ñ, % ,up to 

95 

Dimensions, not more, mm

80 õ 47 õ 42 

Weight, not more, kg

0.12

IP rating

IP41

Ambient class

Boreal climate

Battery life under normal climatic conditions and 
assigned radio exchange period not less than 
30 sec, years, not less

5

Average service life, not less, years

8

3 Scope of Delivery

Each Detector unit package contains the items listed in the Table 2. 

Table 2

Name

QNT

Wireless passive infrared detector «Pyrone-SH2-RK»

Lithium power supply battery CR123A

Resistor C2-23-0.125 W 5.1 k

 

Screw 3-3õ30.016

Wall plug NAT 5õ25 SORMAT

Wireless passive infrared detector «Pyrone-SH2-RK». 
Installation Guide

1 pc.

1 pc.

1 pc.

2 pcs.

2 pcs.

1 copy

4 Detection Pattern

Figure 1

5 Indication

The following types of indication are generated by the Detector:
a) «Binding» – procedure of logging of the Detector in the CP;
b) «Identification» indication is activated by relevant commands received 

from the CP, remains active during 15 min or until the Detector cover is 
opened;

c)  LED  indication  of  the  Detector  state  is  activated  after  the  Detector 

cover is closed and remains active during 15 min under conditions:

- other LED indication types absence;
- alarm «Tamper» message is not generated during this time;
-  absence  of  command  from  the  CP  disabling  the  Detector  state 

indication. 

The modes of LED indication are listed in the Table 3.

Table 3 

The Detector State

Indication

Note

End of the «Binding» 

procedure

LED indicator lighting red 

for 2 – 3 sec

«Binding» procedure

LED indicator blinking green 

with 0.25 sec period

The Detector logging in 

the CP

LED indicator blinking green 

with 1 sec period

The Detector logging in the 

CP in two-channel mode

«Identification» 

indication

LED indicator alternate 
blinking red and green

By the relevant command 

from the CP

«Intrusion to Zone 1»

Single-shot LED indicator 

lighting red for 4 sec*

«Identification» indication 

is ON

«Intrusion to Zone 2»

LED indicator blinks red*

Communication Quality 

Appraisal

See sect. Communication Quality Appraising

«Norm in Zone 1»
«Norm in Zone 2»

Indication is OFF

*) 

 the Detector state indication

6 Binding with the CP

The «Binding» mode is intended for the Detector logging in the CP and 

service information exchange.

6.1 Prepare the CP in accordance with CP Installation Guide.
6.2  In  case,  when  it  is  necessary  to  fulfill  logging  of  the  Detector  in

one-channel mode, hook nothing to the connecting blocks.

6.3 Place the power supply battery to the holder, located on the opposite 

side of the Detector PCB.

6.4 Periodical LED indicator blinking green is evidence of binding process.
In  case  of  mentioned  above  LED  indication  absence,  short-circuit 

«RESET» terminals for 2 – 3 sec.

6.5 Successful binding procedure complying is indicated by LED indicator 

lighting red for 2 – 3 sec.

6.6 The time limit for the binding process of the Detector is 100 sec. To 

restart the binding procedure, short-circuit «RESET» terminals for 2 – 3 sec.

7 Communication Quality Appraising

7.1 For radio communication quality appraising it is necessary to:
- place supply battery to the holder plate;
- install the PCB to the base; 
- set the Detector on the assumed place of installation;
- push and then release case tamper.
7.2  After  case  tamper  releasing  the  Detector  generates  case  tamper 

alarm  message,  transmits  it  via  radio  communication  channel  and 
represents communication quality with CP by LED indication in accordance 
with the Table 4.