USE

Set required deflector position as follows:

• 

Activation

 

press 

 to enter the function cycle

 

work on 

 until the intermittent 

 

appears

 

press 

 to confirm

The 

 icon stay fixed.

• 

If the exit angle can be set:

 

press 

 to enter the function cycle

 

work on 

 until the intermittent 

 

appears

 

press 

 

work on 

 

select required position

Each press will select a different position.

 

press 

 to confirm

• 

Switch-off

 

press 

 to enter the function cycle

 

work on 

 until the intermittent 

 

appears

 

press 

 to confirm

The 

 icon disappears.

 

0

Do not manually move the deflector.

Sleep function

The Sleep function allows user to select a 
time period throughout which the equip-
ment will change reference ambient tem-
perature:

 

increasing it in Cooling and 
Dehumidification mode

 

decreasing it in Heating mode

In Smart mode: depending on the oper-
ating mode selected by the programme.

In the Sleep function, fan will decrease 
its set speed by one.

• 

Activation

 

press 

 to enter the function cycle

 

work on 

 until the intermittent 

 

appears

Control panel display shows 

 with 

the period of time.

• 

To set the time period:

 

press 

OFF icon starts blink.

 

work on 

 

press 

 to confirm

• 

Abort:

 

press 

 or 

• 

Alternatively:

 

wait 10 seconds

• 

Switch-off

The Auto Off Timer function can be set si-
multaneously with the Night function. In 
this case the priority will be assigned to 
the Auto Off Timer function.

The Auto On Timer function and the Night 
function can not be set at the same time.

Energy Saving function

The appliance works by adopting energy 
saving logics. The temperature setting values 
are pre-setted by the program.
The Energy Saving function can be turned on 
in the following modes:

 

Heating

 

Cooling

 

Dehumidification

• 

Activation

 

press 

 to enter the function cycle

 

work on 

 until the intermittent 

 

appears

 

press 

 to confirm

The 

 icon stay fixed.

Содержание Wired Touch panel

Страница 1: ...cod Doc 0090216 rev 0 Wired Touch panel 06 2018 EN USER INSTRUCTIONS ...

Страница 2: ...m the product s date of purchase Find the nearest Authorised Technical Support by visiting the website 9 WARNING KeeptheproductpurchasedocumentsfortaxpurposestobepresentedtotheAuthorised Technical Support upon request of a service call under warranty Dear customer Thank you for choosing a R product an innovative and high quality appliance that guar antees wellbeing for a long time This manual cont...

Страница 3: ...ol panel display 2 INSTALLATION 2 1 Receiving the product 2 2 Dimensions and weight 2 3 Storage 2 4 Place of installation 2 5 Positioning 2 7 Electrical connection 3 USE 3 1 Initial settings 3 1 1 Start upT Time setting 3 2 Functions Cooling mode Heating Mode Dehumidification mode Ventilation mode Smart mode Adjusting ventilation speed Hourly programming Horizontal motorised deflector Vertical mot...

Страница 4: ...anagement of the unit s decommissioning 9 Any repair and maintenance inter ventions must be carried out by R Technical Support Service in accordance with the provisions contained in this publication Do not modify or tamper with the unit as dangerous situations may arise and the unit manufacturerwill not be liable for any damage caused 9 This booklet is an integral part of the device and must there...

Страница 5: ...eating 20 24 C 1 4 Unit description Control setting and programming opera tions are carried out with the control panel The electronics modulates the device opera tion according to the temperatures detected by the probes inside the indoor and outdoor units Control panel display The control panel display shows the settings as changed by the user and the detected weather conditions The backlit displa...

Страница 6: ...air deflector activated Sleep function enabled Heat Reclaim Ventilation function enabled Not available Energy Saving function on Filter cleaning function enabled visible in the cycle only when filter cleaning is required Follow me function activated available only for some models 10 C Anti freeze function activated available only for some models Health airflow up Air flow upwards function availabl...

Страница 7: ...Automatic speed enabled Function keys The control panel is equipped with touch function keys which can activate functions such as choosing the operating mode setting the desired temperature timer and the motorized deflector Allows you to switch the display off and on Allow to select the operating mode Decreases the value of the selected parameter Increases the value of the selected parameter Selec...

Страница 8: ...ent envelope must be kept in a safe place Any duplicate must be requested from Riello S p A which re serves to charge the cost 2 2 Dimensions and weight PACKAGING 241 175 58 CONTROLS 86 86 2 3 Storage 9 The product must be stored of according to the regulations in force 2 4 Place of installation The location of the device must be deter mined by the system s designer or by an other competent person...

Страница 9: ... or generally in conditions that might alter the measured temperatures placing the unit less than 1 metre away from radio and video systems 2 5 Positioning The installation requires the positioning of the control panel on the wall 1 Touch panel 2 Base separate the device from base use the base as template mark fixing holes use a drill drill the wall use anchor bolts 1 Connection hole 1 CON1 A B C ...

Страница 10: ... voltage cables make electrical connections according to the diagrams below 1 Indoor unit 2 Wired Touch panel A B C A 1 2 B C 9 The connection is polarised respect the correct sequence Mandatory items make sure that the electrical power supply system is compliant with the current national safety standards for any electrical intervention always refer to the wiring diagrams contained within this boo...

Страница 11: ... values changes by 1 By keeping the key pressed down the value changes faster confirm with Abort wait 10 seconds Alternatively press to cancel and turn off the control panel 9 It is not possible to adjust the time dur ing the setting of the Timer and the Night function 3 2 Functions Cooling mode The Cooling mode allows starting and use of the air conditioner as a producer of cold and dehumidified ...

Страница 12: ...ns Switch off select another operating mode Alternatively press to turn off the control panel Ventilation mode The Fan mode allows the user to turn on only the fan so as to recirculate and filter ambi ent air Activation press in sequence until the appears 9 The equipment will operate at selected ventilation speed 9 During operation in Ventilation mode automatic sped cannot be selected Switch off s...

Страница 13: ...play shows Set required time as follows press to select hours or minutes work on Each time the key is pressed the values changes by 1 By keeping the key pressed down the value changes faster confirm with Abort press or Alternatively wait 10 seconds Switch off press in sequence until all the in dications relative to the time program ming have disappeared 9 Programming remains active even when contr...

Страница 14: ...press to enter the function cycle work on until the intermittent appears press to confirm The icon stay fixed If the exit angle can be set press to enter the function cycle work on until the intermittent appears press work on select required position Each press will select a different position press to confirm Switch off press to enter the function cycle work on until the intermittent appears pres...

Страница 15: ...ding on the oper ating mode selected by the programme 9 In the Sleep function fan will decrease its set speed by one Activation press to enter the function cycle work on until the intermittent appears Control panel display shows with the period of time To set the time period press OFF icon starts blink work on press to confirm Abort press or Alternatively wait 10 seconds Switch off 9 The Auto Off ...

Страница 16: ...writing 10 C press to confirm The temperature value is not fixed at 10 C and it is possible to change Parental lock function Prevent any accidental control by locking re mote control buttons Button locking press simultaneously for 5 seconds Remote control display shows Button unlocking press simultaneously for 5 seconds disappears in the display of the remote control Screensaver function The scree...

Страница 17: ...17 Use mode press for 15 seconds It switches the temperature scale from Fahrenheit to Celsius set temperature 30 in each operating mode press for 15 seconds ...

Страница 18: ...disposal 4 DISPOSAL Packing materials must be disposed of sepa rately in order to be recovered and recycled Equipment at end of life and flat batteries must be disposed of as required by prevail ing law and regulations ...

Страница 19: ......

Страница 20: ... 39 0442 630111 fax 39 0442 630371 www riello it As the manufacturer is constantly improving its products the aesthetic or dimen sional features the technical data the equipment and accessories indicated could be subject to variations ...

Отзывы: