17
4
Gas Type
5
Flow Indicator Type
6
Domestic hot water start wait time
11
Domestic hot water circuit maximum setpoint
20 Induced draught protection function
40
Domestic hot water thermostat operation
41
Displaying domestic hot water input temperature
42
Displaying domestic hot water flow rate
rt
Exiting the menu
rs
Resetting factory settings
Pressing the MENU (B) key confirms the values set.
To exit the TECHNICAL MENU press the "+" or "-" key until “rt” (return)
is displayed. Pressing the MENU (B) key to return to the USER MENU.
Pressing the ON-OFF/RESET (A) key you pass to the OFF state.
If no action is taken, once 2 minutes have passed the appliance exits
the menu and returns to the normal operation screen.
Table of parameters
Nr.
PAR
PARAMETER DESCRIPTION
UNIT OF
MEA-
SURE-
MENT
MIN
MAX
VALUES
FACTORY SETTING
2
Selecting water heater output/capacity
l/min
11
13
17
11
13
17
4
Selecting methane/LPG
0 (METHANE)
1 (LPG)
0 (methane models)
1 (LPG models)
5
Selecting flow switch/flow indicator
0 (FLOW SWITCH)
1 (FLOW INDICATOR)
0
6
Domestic hot water start wait time
s
0,5
10
(steps of 0.5s)
0.5s
11
maximum setpoint of domestic hot water circuit
°C
36
65
65
20
Induced draught protection function
0
1
0 (NONE)
1 (ACTIVE)
1
40
Type of domestic hot water thermostat operation
0 (ABSOLUTE)
1 (CORRELATED)
0
41
Displaying domestic hot water input temperature
°C
42
Displaying domestic hot water flow rate
NOT USED
rt
Exiting the menu
rs
Resetting factory settings
5.18 Reset to factory settings
From the parameters menu, selecting “rs” allows you to reset the bo-
ard parameters to the factory settings (Reset to factory settings).
Pressing the MENU (B) key displays two underscores. Press the "-"
key until the two underscores shift up. Press the "+" key to return to
factory settings.
If you press the MENU (B) key instead of the "+" key the operation is
annulled and you return to the previous menu.
To exit the TECHNICAL MENU press the "+" or "-" key until “rt” (return)
is displayed, at this point pressing the MENU (B) key returns you to the
USER MENU.
Pressing the ON-OFF/RESET (A) key you pass to the OFF state.
If no action is taken, once 2 minutes have passed the appliance exits
the menu and returns to the normal operation screen.
b
If you are replacing the electronic board it is necessary to set the
parameters
2
(11-13-17) and
4
(methane - lpg) depending on the
type of water heater used.
5.19 Reset to factory settings
From the parameters menu, selecting “rs” allows you to reset the bo-
ard parameters to the factory settings (Reset to factory settings).
Pressing the MENU (B) key displays two underscores. Press the "-"
key until the two underscores shift up. Press the "+" key to return to
factory settings.
If you press the MENU (B) key instead of the "+" key the operation is
annulled and you return to the previous menu.
To exit the TECHNICAL MENU press the "+" or "-" key until “rt” (return)
is displayed, at this point pressing the MENU (B) key returns you to the
USER MENU.
Pressing the ON-OFF/RESET (A) key you pass to the OFF state.
If no action is taken, once 2 minutes have passed the appliance exits
the menu and returns to the normal operation screen.
b
If you are replacing the electronic board it is necessary to set the
parameters
2
(11-13-17) and
4
(methane - lpg) depending on the
type of water heater used.